Probes |
Active:
|
| HP / Agilent |
1152A |
2.5 GHz, 0.6 pF, Active Probe |
| HP / Agilent |
1157A |
2.5 GHz Active Probe |
| HP / Agilent |
54701A |
2.5GHz, 0.6pF, Active Probe |
| HP / Agilent |
85024A |
3 GHz, 0.7 pF, Active Probe |
| HP / Agilent |
85025A |
10 MHz - 18 GHz Detector |
| HP / Agilent |
85025B |
10 MHz - 26.5 GHz Detector |
| Tektronix |
P6046 |
DC - 100 MHz 50 Ohm FET Differential Probe |
| Tektronix |
P6201 |
DC - 900 MHz Active FET Probe |
| Tektronix |
P6204 |
DC - 1 GHz Active FET Probe |
| Tektronix |
P6205 |
DC - 750 MHz Active FET Probe |
| Tektronix |
P6245 |
≥1.5 GHz Bandwidth (Typical, Probe Only) Active Probe for SMDs |
| Tektronix |
P6202A |
DC - 500 MHz Active FET Probe |
| Tektronix |
P7240 |
4 GHz Active Probes |
| Tektronix |
P7330 |
High Performance Differential Probe |
Detectors:
|
| Agilent |
11664A |
100 MHz - 18 GHz, Detector |
| Agilent |
11664E |
10 MHz to 26.5 GHz, Detector |
| Agilent |
85025A |
10 MHz to 18 GHz, Detector |
| Agilent |
85025D |
10 MHz to 50 GHz, Detector |
Current:
|
| AEMC |
SR651 |
1000A Current Probe 1mV/A Output, 2" clamp |
| AH Systems |
BCP-510 |
20 Hz - 1 MHz Current Probe |
| AH Systems |
BCP-511 |
20 KHz - 100 MHz Current Probe |
| AH Systems |
BCP-512 |
80 MHz to 1 GHz Current Probe |
| AH Systems |
BCP-520 |
10 KHz - 500 MHz Current Probe |
| Dranetz/BMI |
CT150 |
0.25-150A AC Clamp On Current Probe .47" max cable |
| Dranetz/BMI |
CT300 |
10-300A AC Clamp On Current Probe, 2" max cable |
| Dranetz/BMI |
CT3000 |
100A - 3000A AC Clamp On Current Probe, 1.97"x5.31" |
| Fluke |
80i-110s |
AC/DC Current Probe 0.05A - 100A DC - 1 kHz / 20 kHz, 0.46" |
| Fluke |
i1010 |
Current Probe 600A AC 1000A DC Clamp On 1mV/A |
| Fluke |
i400s |
40A & 400A, 10 or 100 mV/Amp output AC Current Clamp |
| Fluke |
Y8100 |
AC/DC Hall Type Sensor <0.75" Conductor Diam. Current Probe |
| Solar |
9108-1N |
10 kHz - 100 MHz Current Injection Probe, Type N |
| Solar |
9123-1N |
10 kHz - 500 MHz Current Monitor Probe, 40A Max, Type N(f) |
| Solar |
9125-1 |
20 Hz - 500 MHz Calibration Test Fixture for Injection Probes |
| Solar |
9142-1N |
2 MHz - 500 MHz Injection Probe, 200W max |
| Solar |
9335-2 |
10 kHz - 10 MHz 1.2/2.4/25/50 ohm Injection Probe |
| Solar |
9357-1 |
20 Hz - 100 MHz 50ohm Calibration Test Fixture for Injection Probes |
| Tektronix |
A6302 |
DC - 50 MHz, 20A, <0.15" Conductor Diam. Current Probe |
| Tektronix |
A6303 |
100A,500A Peak DC -10 MHz Current Probe (reqs amp) |
| Tektronix |
AM503 |
DC - 50 MHz Current Probe Amplifier |
| Tektronix |
AM503B |
1 mA - 50A/Div Current Probe Amplifier, reqs probe |
| Tektronix |
AM503S |
Current Measurment System w/Probe, Amp & Chassis |
| Tektronix |
A6303XL |
DC - 10 MHz 100A Current Probe (reqs AM503B/AM5030) |
| Tektronix |
A6304XL |
DC - 2 MHz 500A Current Probe (reqs AM503B/AM5030) |
| Tektronix |
CT5 |
20 Hz - 1.2 kHz, 1000A, <1.5" Conductor Diam. Current Probe |
| Tektronix |
P6022 |
935 Hz - 120 MHz, 6A, <0.1" Conductor Diam. Current Probe |
| Tektronix |
P6303 |
100A,500A Peak DC - 10 MHz Current Probe (reqs amp) |
| Logic (see Logic Analyzers) |
Gauss:
|
| FW Bell |
HTF99-0608 |
Heavy-duty Aluminum Stem Probe |
| FW Bell |
HTM99-0608 |
Transverse Heavy Duty Probe |
| FW Bell |
HTF95-0608 |
Heavy-duty Gauss Probe |
| FW Bell |
ZOA99-3208 |
Three-Axis Probe |
Isotropic:
|
| Amplifier Research |
FL7040 |
40 GHz, Electric Field Probe |
| Amplifier Research |
FM 7004 |
Field Monitor, 100 kHz - 60 GHz |
| Amplifier Research |
FP7018 |
Electric Field Probe,
3 MHz – 18 GHz, 1000 V/m |
| Narda |
8511 |
300 kHz - 100 MHz E & H Field Radition Meter w/probe |
| Narda |
8600 Series |
Narda 8600 Series Isotropic Probes |
| Narda |
8741D |
300 kHz - 50 GHz E-Field Probe |
| Narda |
8754D |
300 kHz - 10 MHz E-Field Probe |
| Narda |
8760D |
300 kHz - 3 GHz Isotropic Probes |
| Narda |
8761D |
300 kHz - 3 GHz Isotropic Probes |
| Narda |
A8722D |
300 kHz - 50 GHz "Shaped" Probe (freq resp weighted) E |
| Narda |
A8742D |
300 kHz - 3 GHz "Shaped" Probe (freq resp weighted) E |
| Narda |
EA5091 |
300kHz - 50 GHz "Shaped" E-Field Probe, FCC |
| Narda |
EHP-50C |
Up to 100 kHz E & M Isotropic Probe |
| Narda |
EMR-20C |
100 kHz - 3 GHz E-field Isotropic Probes |
| Narda |
EMR-30 |
100 kHz - 3 GHz E-field Isotropic Probes |
| Narda |
ELT-400 |
1 Hz - 400 kHz Exposure Level Tester |
| Narda |
SRM-3000 |
100 kHz - 3 GHz Selective Radiation Meter (SRM) |
| Narda |
SRM-3006 |
9 kHz - 6 GHz Selective Radiation Meter |
| Schaffner |
EMC-20 |
100 kHz - 3 GHz E-field Probe |
| Wandel & Goltermann |
EMR-300 |
100 kHz - 3 GHz E & H Field Radiation Meter |
Optical Electrical Converter:
|
| Tektronix |
P6703B |
1100 nm - 1700 nm Optical-to-Electrical Converter w/TEKPROBE® Interface |
| Tektronix |
P6701B |
500 nm - 950 nm or 1100 nm - 1700 nm Optical-to-Electrical Converter w/TEKPROBE® Interface |
Test Kits:
|
| Agilent |
E2625A |
Communication Mask Test Kit |
Voltage:
|
| Fluke |
80K-40 |
1000:1, 40 kVDC or Peak AC, 28 kVrms AC, 60 Hz Probe |
| HP / Agilent |
41941B |
50 Ohm, 10 Hz - 100 MHz Impedance Probe Kit |
| Narda |
A8722 |
Frequency Range: 300 kHz, Measurement Range: 50 GHz 0.3 to 300% of standard |
| Tektronix |
1103 |
Probe Power Supply |
| Tektronix |
P5205 |
100 Mhz High Voltage Differential Probes |
| Tektronix |
P6015A |
1000:1, 20 kVDC, 75 MHz, 40 kV Peak Probe |