| Bulk Call Generator - T1 Basic
Unit
GENERAL
Description:
Multiple port, programmable, telephone call generator/call terminator with coincident
recording of attempts, average dial-tone delay, dial tone delays, no dial tones, no rings,
no confirmation tones, average post-dial delay, completions and run time data.
Construction: Modular, plug-in printed circuit boards.
Capacity: From 1 to 30 Originate and Terminate Ports ( maximum
capacity 450 Originate and 450 Terminate ports when chaining multiple sets).
ELECTRICAL
Originate Ports
Types: Loop start, ground start, 2 and 4-wire E&M, and T1
(DS1 1.544 Mbps, 24 Channel, D3/D4 format, DSX1 levels).
Impedance: 900 Ohms AC (1200 Ohms DC loop resistance simulated)
or 600 Ohms AC (600 Ohms DC loop resistance simulated).
Signaling: Dial pulse; multi-frequency (MF), both analog and
digitally-generated; and dual tone multi-frequency (DTMF / Touch Tone), with either shared
tone generator or (for loop/ground start Line Cards) with individual Line Card tone
generators.
Terminate Ports
Types: Loop start (1 R.E.N.), 2 and 4-wire E&M, and T1.
Incoming Call Detect: Senses ringing (or equivalent) energy and
trips ringing (shorts loop with 1200 ohms DC, 600 ohms optionally, impedance for loop
ports). E&M and T1 ports perform programmed wink/delay sequence before
answering.
T1 Ports: DS1, 1.544 Mbps, 24 Channel, D3/D4 format, DSX1
levels, E&M signaling emulation.
Data Collection
Registers: There are ten (10) data collection registers for
each line as listed below:
- Attempts
- Average Dial-Tone Delay
- Dial Tone Delay
- No Dial Tone
- No Ring
- No Tone
- Average Post-Dial Delay
- Completions
- Run Time
- Terminations
Register Capacity: Each counting register will accumulate
counts to 65535. |