ARTI HHPC-6 ARTI HHPC6 Mobile Particle Counter

THe ARTI HHPC-6 is an effective mobile solution for particle monitoring in cleanrooms, using a single counter forregular measurements of the cleanliness at many locations and trouble shooting particle contamination problemsin cleanrooms.It may also serve as a reference counter for stationary particle monitoring systems, investigating alarm situations orfor integrity testing of cleanroom walls, clean benches and filter ceilings by scanning for leakage detection.HHPC-6 displays 6 size channels from 0,3 to 5 µm, it reports the particle concentration as well as temperature andhumidity and stores 500 sample records with date, time and sample location (label).

Typical Monitoring Applications for the ARTI HHPC-6:

  • Cleanrooms and clean benches in production- and laboratory areas

  • Operation rooms or clean benches and isolation chambers in hospitals or pharmacies

  • Monitoring in pharmaceutical and medical production or in filling and packaging areas of the food and beverage industry

  • Air monitoring in computer rooms, in automobile paint shops or filter production

Specifications:
Size channels 0,3 µm; 0,5 µm; 0,7 µm; 1.0 µm; 2.0 µm; 5.0 µm
Relative Humidity ±5%, 20-90%, non-condensing
Temperature ±2°C, 10-40°C
Memory 500 Samples
Data transferred

Date, Time, Counts, Relative Humidity, Temperature, Sample volume, Alarm, Label

Operation modes CONCENTRATION, TOTALIZE, AUDIO
Alarms Counts, Battery empty, Sensor fault
Display Illuminated graphics-LCD
Delay-time 0-24 h
Interface RS232C and RS485 via RJ-45
Operating time continuous 5-6 h
Recharging time 2 h
Housing Metalised plastic
Laser life time >36000 h @ 25°C
Flow rate 2,83 L/min (0,1 CFM) regulated electronically
Calibration PS-Latex beads in air
Counting efficiency

50% at 0,3 µm
100% at 0,45 µm

Coincidence loss

5% at 2.000.000 Particles/cft
(70.000.000 Particles/m3)

Dimensions (cm) (WxHxD) 11,4 x 21 x 5,7
Weight 1 kg
Charger 12 VDC at 2,5 A, 90-250 VAC, 50-60 Hz
Battery NiMH, 4,8 V at 4,5 Ah
CE-Conformity EMV; Low Voltage

Please contact us for more information on the ARTI HHPC-6

Agilent
E4437B

Agilent E4437B
Yokogawa
WT1600B


Yokogawa WT1600B
Anritsu
MS2026A

Anritsu MS2026a
Megger
DLRO-200-115

Megger DLRO-200-115

Teseq
NSG437
Varian 956 Porta Test
Solar
7054-1

Chauvin Arnoux 6121
Privacy Notice Site Map Terms of Use
 
Copyright © 1996-2008  |  Advanced Test Equipment Rentals  |  All Rights Reserved