Associated Research 3160 Hyamp III Ground Bond Tester
The Associated Research 3160 Hyamp III Ground Bond
Tester features an enhanced graphic LCD. It provides 60 Amps of
Ground Bond test current. The unit was designed to
provide enough Ground Bond test current for products with higher input
current ratings. The Associated Research 3160 Hyamp III Ground Bond
Tester can be used stand alone or
interconnected to the Hyamp III family of Hipot testers to
form a complete test system. It can also be controlled through enhanced
PLC Remote Control. It features the latest technology and is well suited
for all manual Ground Bond test applications that require more than 30
Amps of test current.
Features
- Patented VERI-CHEK® feature prompts users through steps to validate the instrument's operation
- Graphic LCD provides intuitive menu system to simplify the entire testing process from set-up to results
- Patented CAL-ALERT® feature alerts the operator that the tester is due for re-calibration PLC Remote Control allows operators to remotely control the Ground Bond tester
- 10 Memories with 3 Steps per memory for storing and recalling test parameters
- Interconnects with an Associated Research Hipot tester to form a complete test system
- 4 wire measurement and milliohm offset for accurate Ground Bond test results
- Electronic Dwell timer for more consistent and reliable testing
Specifications
| Input |
| Voltage |
115/230 VAC ± 10%, user selectable |
| Frequency |
50/60 Hz ± 5% |
| Fuse - 3130 |
6.3 A, slo-blow 250 VAC |
| Fuse - 3140 |
10 A, slo-blow 250 VAC |
| Fuse - 3130 |
15 A, slo-blow 250 VAC |
| Ground Bond Test Mode |
| Output Rating |
Current: |
1.00 - 60.00 A AC |
| Voltage: |
9 VAC, fixed |
| Resolution: |
0.01 A |
| Regulation: |
± (2% of setting + 0.02 A) |
| Output Frequency |
Range: |
50 / 60 HZ, User Selectable |
| Dwell Time Setting |
Range: |
0 and 0.5 - 999.9 secs |
| 0 for continuous running |
| Resolution: |
0.1 sec |
| Accuracy: |
± (0.1% of setting + 0.05 secs) |
| Max. & Min. Limits |
Range: |
| 0 - 150 mohm for 30.01 - 60.00 A |
| 0 - 300 mohm for 15.01 - 30.00 A |
| 0 - 600 mohm for 6.00 - 15.00 A |
| Accuracy: |
±(3% of setting + 3 mO) |
| Offset Capability |
Range: |
0 - 100 mΩ |
| Resolution: |
1 mΩ |
| Accuracy: |
± (2% of setting + 2 mΩ) |
|