| INPUT |
115/230V
selectable, ± 15% variation 47 - 63 Hz |
| FUSE |
115
VAC, 230VAC -- 10A fast acting 250VAC |
| OUTPUT
ADJUSTMENT |
Current:
AC 3 - 31 Amps, 0.01 Amp/step
Regulation: ± (2% of Setting +
0.02A)
Voltage: AC 3 - 8 Volts, 0.1 Volt/step |
| OUTPUT
FREQUENCY |
50/60
Hz selectable |
| HIGH
TRIPRANGE |
0
- 600 mfor 3 - 12 Amps, 1 m/step
0 - 150 mfor 3 - 31 Amps, 1 m/step
Accuracy: ± (2% of setting + 2 m) |
| LOW
TRIP RANGE |
0
- 600 mfor 3 - 12 Amps, 1 m/step
0 - 150 mfor 3 - 31 Amps, 1 m/step
Accuracy: ± (2% of setting + 2 m) |
| MILLIOHM
OFFSET |
Max.
Offset Capability: 100 m,1m/step
Accuracy: ± (2% of setting + 2 m) |
| CURRENT
DISPLAY |
4
digits
Range: 0 - 31 Amps
Resolution: 0.01 Amp/step
Accuracy: ± (3% of Reading + 0.03 A) |
| OHMMETER
DISPLAY |
3
digits
Range: 0 - 600 m
Resolution: 1 m/step
Accuracy: ± (2% of Reading + 2m) |
| TIMER
DISPLAY |
4
digits
Range: 0 - 999.9 seconds
Resolution: 0.1 seconds /step
Accuracy: ± (0.1% of Reading + 0.05 seconds) |
| DWELL
TIMER |
0
and 0.5 - 999.9 seconds, 0.1 second/step
"0" for continuous running
Accuracy: ± (0.01% of Setting + 0.02 seconds) |