Bruel & Kjaer 2651
Bruel & Kjaer 2651 with 2805 2651 - Charge Amplifier
  • General purpose vibration and shock measurements particularly with Uni-Gain® Accelerometers
  • Multichannel measuring systems and vibration test control loops
  • Preamplifier for piezoelectric impedance heads and force transducers
  • Wide frequency range 0,003 Hz to 200 kHz
  • Output sensitivity settings of 0,1 - 1 - 10 mV/pC
  • Built-in integrator converts acceleration signal to velocity
  • Grounded, plus Floating input mode isolated from output ground
  • Switchable lower frequency limits

Specifications

  • Charge Input: via 10-32 UNF coaxial and multi-pin screened sockets
    * Input Modes: "Grounded"; "Floating"
  • Amplifier Sensitivity: 0,1 mV/pC, 1 mV/pC and 10 mV/pC
  • Signal Output: via 10-32 UNF coaxial and multi-pin screened socket
    * Max Output: 10 V (10mA) peak
    * DC Offset: < ± 10 mV with dual polarity supply or half single polarity supply voltage
  • Frequency Range:
    * - 3 dB Lower Limit: 1 Hz for all three sensitivity settings or 0,003 Hz; 0,03 Hz and 0,3 Hz for 0,1; 1 and 10 mV/pC respectively
    * - 3 dB Upper Limit: > 200 kHz for 0,1 and 1 mV/pC sensitivity and > 150 kHz for 10 mV/pC
  • Integrator: converts acceleration to velocity proportional signal
    * Frequency Range: 10 Hz to 10 kHz (-10% limits)
  • Power Requirements:
    * Dual Polarity: ± 6 to ± 18 V DC
    * Single Polarity: + 12 to + 35 V DC
    * Supply Current: 15 mA nominal increasing to 30 mA with "Overload" LED lit

2805 - Power Supply

  • Power supply for preamplifiers in vibration measurement set-ups
  • Power supply for instruments operating on 14 V and 28 V DC
  • Used for supplying the following instruments with the direct current necessary for their operation:
    * Charge Amplifiers types 2634, 2635 and 2651
    * Accelerometer Calibrator Type 4291
    * Vibration Meter Type 2511
    * Tunable Band Pass Filter Type 1621
  • 12 outputs, 2 channels
  • ± 14 V or 28 V or DC output

Specifications

  • Output: 2 channels short circuit protected
  • Output Connections: for each channel 5 x 10 - 32 UNF sockets, also 1 x 6 pin Bulgin plug JP 4705
  • Output Voltage: 28 Volts or ± 14 Volts
  • Output Current: Max. 200 mA per channel
  • Power Requirement: 100, 115, 127, 220, 240 Volts (50 to 400 Hz)

Haefely
ECOMPACT4

Haefely Ecompact 4
CA Instruments
5001ix


California Instruments 5001ix
Voltech
PM6000

Voltech PM6000
IFI
T4026-40

IFI T4026-40

Teseq
NSG437
Varian 956 Porta Test
Solar
2654-1

Solar 2654-1
Terms & Conditions Privacy Notice Site Map Terms of Use
 
Copyright © 1996-2008  |  Advanced Test Equipment Rentals  |  All Rights Reserved