California Instruments 2003RP AC Power Source, 3 Phase, 675 VA per Phase
Offering simple rotary front panel
controls, the 2003RP programmable
AC power source is ideally
suited for a wide range of three
phase AC power applications.
Selectable input voltage ranges
allow this product to be used anywhere
in the world to provide a convenient
source of variable utility
power for the testing and evaluation
of domestic and commercial
equipment.
In addition, the frequency range
extends to 5000 Hz, making this
product ideal for a wide range of
avionics and defense applications.
Accurate measurement functions
are available as an option to eliminate
the need for external test
equipment in many test setups.
Voltage, current, peak current,
power, and power factor for each
individual phase output can be read
on the large LCD display or over
the bus. A programmable current
limit function provides overload protection
of the unit under test.
California Instruments 2003RP Features:
- 675 VA Output Power per Phase -
5.0 ARMS current per phase
- 16 Hz to 5000 Hz Frequency Range:
Commercial, Military and Avionics
applications
- High Peak Current Capability:
Drives a wide variety of non-linear
loads
- Accurately measures
- TRMS Volt
- TRMS Current
- Peak Current
- Crest Factor
- Real Power
- Power Factor
- Remote Control:
IEEE-488 and RS232C Interface for
automated test applications. Includes
Windows™ operating software
California Instruments 2003RP Specifications: |
| Controller |
|
Type |
Programmable |
|
Controls |
Digital
Encoders |
|
Readouts |
dual
4 digit LCDs |
| Output |
|
No. of Phases |
3 (A,B,C) |
|
Phase Angles |
A = 0°, B = 240°, C = 120° |
|
AC Power |
Max 675 VA per phase |
|
Load
Connection |
floating
neutral Rear panel terminal block
optional Universal front panel sockets |
|
Voltage |
|
Ranges (High / Low) |
0
- 270 / 0 - 135 V RMS |
|
Accuracy |
16
Hz - 100 Hz ± 0.1 % FS
100 Hz - 2000 Hz ± 0.2 % FS |
|
Resolution |
0.1
V |
|
Load
Regulation |
remote
sense, 16 - 500 Hz, ± 0.1 % FS |
|
Line
Regulation |
10
% Line change ± 0.02 % FS |
|
T.H.D. (into a resistive
load) |
16
Hz - 100 Hz 0.5 typ./ 1.0 max. %
100 Hz - 5000 Hz 1.0 typ./ 2.0 max. % |
|
Output
Noise |
<
0.1 typ. V RMS |
|
Frequency |
|
Range |
16
- 5000 Hz |
|
Accuracy |
±
0.02 % |
|
Resolution |
16.00
Hz - 80.00 Hz 0.01 Hz
80.1 Hz - 800.0 Hz 0.1 Hz
800 Hz - 5000 Hz 1 Hz |
|
Current |
|
RMS
Current |
High
/ Low V range 2.5 / 5.0 A RMS |
|
Peak
Current |
High
/ Low V range 7.5 /15.0 A |
| Protection |
|
Adj.
Current limit |
Resolution
0.1 A RMS
Modes Const. Current or Const. Volt |
|
Over
Temperature |
- |
|
Over
Voltage |
- |
| Input |
|
Connection |
Rear
panel terminal block |
|
Line
Voltage |
2
wire + GND 103 - 127 V or 187 - 253 V V RMS |
|
Line
Current |
47
- 440 Hz |
|
Holdup
Time |
10
ms |
|
Isolation |
Input
to Chassis/Output 1350 / 2200 V |
|