(Complete system,
including personal computer)
Click
here for a screenshot of the software |
|
Pre-Compliance Harmonics and Flicker Test System
The PACS-1 pre-compliance harmonics and flicker test system provides a cost effective solution for testing products to EN61000-3-2 harmonics, and EN61000-3-3 Flicker standards during internal product qualification and development
stages. Using line AC power from 100 - 240 Vac 50 Hz, the PACS-1 uses proprietary software algorithms to compensate for line distortion. Hence, test results will be virtually identical to those that will be obtained with a full compliance test system. This ensures that results are consistent and repeatable, regardless of prevailing line conditions
Features
- AC Line Distortion Compensation - PCTS Software compensates for AC Line distortion.
- PC Based Operation - Simple to use Windows GUI automates and documents test procedures and easily accommodates future IEC standard changes.
- Upgradable to Full Compliance Leve - PCTS can be field upgraded to full compliance by adding a California Instruments AC Power Source.
- EN 61000-3-2 Harmonics
- EN 61000-3-3 Flicker
Specifications
| Voltage Range |
0.001 - 312.0 V rms |
| Maximum Input Voltage |
1000 V rms |
| Current Ranges (Auto Ranging) |
4, 16, 40 A rms |
| Power Range |
0.1 - 12,500 Watts |
| Power Factor Range |
0.000 - ± 1.000 |
| Crest Factor |
20:1 |
| Frequency Range |
50.0 ± 0.5 Hz |
| Flicker Pst Range |
0.1 - 10 Pst |
| Flicker Pit Range |
0.1 - 10 Pit |
| Weight |
17.6 lbs. |
Provides the following certified IEC compliance tests with the optional California Instruments 1251RP Programmable AC Power Source or other Power Source (Upgrades to full compliance with the use of the C.I. 1251RP):
|