PX5-XFAST PowerXplorer Power Quality Meter
The Dranetz-BMI PowerXplorerTM PX5 is a portable, hand-held, eight-channel power
quality meter/monitor. This cutting-edge power quality instrument is designed with a
color liquid crystal display (LCD) 1/4 VGA, using touch screen technology. It can
monitor, record and display data on four voltage channels and four current channels
simultaneously.
PX5 is designed to meet both the IEEE 1159 and IEC 61000-4-30 Class A standards for
accuracy and measurement requirements. It can do PQ-optimized acquisition of power
quality related disturbances and events. It is designed with a statistical package called
Quality of Supply (QOS), with monitoring and setup protocols set to determine voltage
measurement compliance required for EN50160 monitoring. European standard
EN50160 requires that measurement parameters must be within a specified percentage
for 95% of the time.
Model PX5-XFAST is equipped with the high speed sampling analog board for
microsecond
transient detection digitization and analysis. The PX5-XFAST performs
measurements for
50/60 Hz power frequency systems.
Measured Parameters
- Voltage Type: 4 full differential, DC coupled
Channels A, B, C, D
- Input Range: 10 - 600 Vrms
- Input impedance: 16 MΩ, minimum, Input to Input
- Crest factor: Maximum 1.7 at full scale
- MS Accuracy: ±0.1% of Reading, ±0.05% Full Scale, over 7KHz bandwidth (1 second rms readings)
- Transient Input: 50 - 1000 Vpeak
- Transient Accuracy: ±10% of Reading, ±0.5% Full Scale for Pulses > 10uS
- Transient Duration: 2uS minimum CMMR: -80 dB
- Supply rate: 256 samples per cycle; rms computed on 1/2 cycle step
- Current Type: 4 full differential, DC coupled. Channels A,B, C, D
- Input Range: 10 - 200% of Rated Probe Input (Dranetz-BMI probes)
- Channels A,B,C, D crest factor: Maximum of 3 at full scale.
- RMS Accuracy: ±0.1% of Reading ±0.05% Full Scale plus Probe Accuracy, 3KHz bandwidth (1 second rms readings)
- Transient Input: 3 times Probe Rated Nominal Input (Dranetz-BMI probes)
- Transient Accuracy: ±10% of Reading, ±0.5% Full Scale over 1MHz bandwidth (option) > 10uS
- Transient Duration: depends on probe bandwidth CMMR: -80 dB
- Supply rate: 256 samples per cycle; rms computed on 1/2 cycle step
Technical Specifications
| Frequency |
Three ranges, user selectable. |
|
For Model PX5-XFAST: • 30 - 70 Hz default, with up to 25% Vthd • 15 - 30 Hz |
|
For Model PX5-400: • 30 - 70 Hz default, with up to 25% Vthd • 380 - 440 Hz (reduced accuracy with 32 samples/cycle) |
|
Accuracy: ±0.2% of reading |
| Environmental |
All specifications are met over the operating range with influence factors as per IEC 61000-4-30 Class A. |
|