EMCO 3810-2
HP / Agilent 11967D
EMCO 3810-2 aka HP / Agilent 11967D EMCO 3810/2 LISN / PLISN

Multi-line low pass filter networks used for conducted emissions measurement.  They are placed between the power mains and the EUT ( Equipment Under Test ) to stabilize line impedance, provide a 50 ohm RF connection, and eliminate unwanted RF signals from the line supply.   Designed to be used with a signal analyzer for making FCC 15, VDE 0871 & 0875, and EN55022 conformance measurements.

An Artificial Hand circuit which conforms to EN55014 is included.  The circuit is useful for testing hand-held equipment which does not have a connection to protective earth ground.

Features:

  • Frequency Range: 9 kHz to 30 MHz
  • Continuous Current Rating: 10A
  • Earth Line Choke
  • Artificial Hand Network

Applications
Test Type: FCC-15, VDE 0871, VDE 0876, EN55022

Electrical Specifications

  • Lines Plus Ground: 2
  • Frequency Range: 9 kHz - 30 MHz
  • Power Source Frequency: 60 Hz ( 50 Hz optional )
  • Maximum Current: 10 A
  • Maximum Voltage:
    125 VAC Line to Ground
    ( 250 VAC Line to Ground optional )
  • Network Inductance Impedance: 50µH / 250µH; 50 ohm
  • Power In Connector: IEC power inlet with customer specified plug
  • Power Out Connector: NEMA®

Please contact us for more information on the EMCO 3810/2


Agilent
E4437B

Agilent E4437B
Yokogawa
WT1600B


Yokogawa WT1600B
Anritsu
MS2026A

Anritsu MS2026a
Megger
DLRO-200-115

Megger DLRO-200-115

Teseq
NSG437
Varian 956 Porta Test
Solar
7054-1

Chauvin Arnoux 6121
Chroma
63209
Chroma 63209
Privacy Notice Site Map Terms of Use
Copyright © 1996-2007  |  Advanced Test Equipment Rentals  |  All Rights Reserved