| Specifications |
| Parameter |
Value |
| Fiber
Splicing Capability |
SM,
MM, NZ-DS, DS, attenuation and specialty splicing |
| Splice
Loss |
0.02dB with SM fiber, 0.01dB with MM,
and 0.04dB with NZ-DS fiber,
0.04dB with DS fiber (all results typical) |
| Return
Loss |
>60dB |
| Cleaved
Fiber End Angle Alarm |
Programmable
up to 5° |
| Fusion
Splices/Battery Charge |
BTR-06S: 80 splices (including splice
protection sleeve tube heater cycle)
BTR-06L: 160 splices (including splice protection sleeve tube heater
cycle) |
| Viewing
Method |
Dual CCD cameras with high resolution
5.6 LCD monitor with 295X and147X
magnification, external RCA jack for NTSC video signal |
| Splice
Sleeve Compatibility |
40mm,
60mm sleeves, micro sleeves |
| Atmospheric
Compensation |
Fully automatic up to 5000 meters
(16,400 feet) with automatictemperature
compensation |
| Operating
Temperature |
-10°C
to +50°C |
| Attenuation
Capability |
Programmable
from 1dB up to 15dB |
| Splice
Data Storage |
2000
splice data records |
| Splice
Modes |
Up
to 60 pre-programmed, 40 user programmable (100 total) |
Splice Protection SleeveHeater
Modes |
Up
to 20 pre-programmed, 10 user programmable (30 (total) |