Graphtec WR7600 Thermal Arraycorder
The Graphtec WR7600 Thermal Arraycorder is not only
outstandingly dynamic but also is, at a mere 7.5 kg, the lightestweight
design in its class. It is a truly active recorder and can run on either
an AC or DC power supply. This high-tech recorder can play an active role
in virtually any conceivable measurement site and environment, offering
new possibilities that conventional recorders until now were not able to
provide. The Graphtec WR7600 Thermal Arraycorder can run on a DC power
supply at sites where AC power is unavailable, and it is so lightweight
you can carry it with one hand. This single recorder can easily record at
sites that were formerly inaccessible using conventional recorders.
| Specifications: |
| Measuring
functions |
Direct mode : Y-T, X-Y, logging
Memory mode : Y-T, X-Y |
| No.
of channels |
Four |
| Channel
configuration |
(Specify when ordering)
(1) 4 analog amps
(2) 3 analog amps + 1 logic amp
(3) 2 analog amps + 2 logic amps
(4) 4 logic amps
(There are 8 channels per logic amp) |
Event marking between channels |
4 channels
(only in Direct Y-T mode) |
| Memory
capacity |
32
k words/ch (1 word = 8 bits) |
| Recording
method |
Thermal-sensitive
recording |
Recording resolution |
6
dots/mm |
| Recording
paper |
Roll paper (110-mm wide x 40-m long) |
Recording width
(Signal recording amplitude) |
Approx
. 83 mm (500 dots) |
Waveform monitor
(for analog amps)
|
Recording position independently
displayed by 12-dot LED for each channel |
| Channel
identification |
Channel markings (appended to analog
recording) |
| System
annotation |
Date, time, recording mode, data
number, trigger conditions, sampling speed, chart speed, scaling,
measurement start/stop times, trigger time, time axis |
| Channel
annotation |
Channel number, amp type, channel ID,
input ON/OFF, sensitivity, position (digital values) |
| Operation |
Interactive settings using an LCD
panel |
Comment
functions
(User annotation) |
8 characters per channel can be input
via the control panel Comment input via the GP-IB interface |
| Remote
functions |
Command control via TTL remote
functions (start/stop, EXT clock input) and the GP-IB interface |
| Interface
functions |
Control of WR7600 via the GP-IB
interface (optional, please check availability) Readout of input
data |
| Operating
environment |
0
to 40 C, 35 to 85% RH |
| Rated
power supply |
100 VAC , 10%, 50/60 Hz
(equipped with 115, 200, 220, 240V selector) |
|