Programmer
Networks
PN 248 - FCC Telecom
Mode 1
- Voltage (open-circuit)
Peak: 0-1.5 kV
Waveshape: < 10 X > 160
- Current (short-circuit)
Peak: > 200A
Waveshape: < 10 X > 160
Mode 2
* Voltage (open-circuit)
Peak: 0-800V
Waveshape: < 10 X > 560
*Current (short-circuit)
Peak: > 100A
Waveshape: < 10 X > 560
PN 250 - Classic Telecom
(Requires Model 210 Energy Storage Unit; surge rate, 2/minute)
Mode 1
* Voltage (open-circuit)
Peak: 0-1.5 kV
Waveshape: 1 kV/µsec
* Current (short-circuit)
Peak: 250A
Waveshape: 10 x 1000
Mode 2
* Voltage (open-circuit)
Peak: 0-1 kV
Waveshape: 10 x 1000
* Current (short-circuit)
Peak: 100A
Waveshape: 10 x 1000
Note: Other networks also available upon request. Please inquire with your
Sales Rep. |
|
Surge Generator/Monitor
- Voltage to 6000 volts, current to 2000 amperes, plug-in
dependant
- Positive and negative pulses
- Precise, selectable waveshapes
- Rise time to 100kV/microsecond
- Four-wire output connection
- Digital display of peak V and I
- Go/no go display of peak V and I
- V and I monitor outputs
- Human engineered for safe operation
- Expandable through options & accessory equipment
Generator
- Output: single-shot pulse
- Actuation: dual switch system
* Charge establishes internal potential; Pulse applies stored potential to output
via pulse-forming network
- Pulse Repetition Rate: 6/minute, maximum, standard; determined automatically by
the Programmer Network
- Leading Edge Polarity: positive and negative
- Waveshapes, Open-Circuit Voltage and Short-Circuit Current: impulses have
exponential rise and decay, except voltage waves with linear fronts
Monitor
Includes all waveforms, whether full or chopped
- Voltage Display
- Current Display
Go/No-Go
Go/No Go indicators for voltage and current peaks, based on digital comparison with
front panel switch settings.
Analog Outputs
Outputs: Voltage and current: 5V; full range |