| Synchronization Interfaces |
- Internal: SONET, 51.84 MHz ± 10 ppm; DS3,
44.736 MHz ± 10 ppm; DS1, 1.544 MHz ± 100 ppm
- External: SONET, 51.84 MHz ± 100 ppm; 155.52
MHz ± 10 ppm
- Loop Timing: Recovered Rx Clock to Transmitter
- BITS Timing: DSX-1 input used as Tx Timing Reference
|
| Payloads |
DS3 Payload
- General: A single internally or externally generated
asynchronous DS3 signal is mapped into an STS-1 payload
- Frame Patterns: M13, C-bit, unframed
- Payload Patterns: 223-1, 215-1,
AIS, Idle, All Ones
Tributary VT1.5 Payload
- General: A single internally or externally generated
asynchronous DS1 signal is mapped into a specified STS-1 payload
virtual tributary
- Active Channel Pattern: PRBS 223-1, QRW,
3/24, 55 Octet and All Ones
- Framing: Unframed, SF, ESF, SLC96
- Modes: Floating, Bit Asynchronous, simplified H4
coding. Bit Synchronous Locked, Byte Floating, Byte Locked.
- VT Pointer Justification: Positive and negative
single justifications. New Data Flag (NDF) operations cause the
pointer to jump to a new location.
- Payload Structure: DS1 payload is mapped into one
channel or all 28 channels
STS-c Payload: An internally generated 223-1
PRBS sequence with valid path overhead |
| Alarm and Error Generation |
- Section: Loss of Signal (LOS), Loss of Frame (LOF),
BER, Single error inject
- Line: Alarm Indication Signal (AIS), Far End Receive
Failure (FERF), Bit Error Rate (BER), Single error inject
- Path: Loss of Pointer (LOP), STS Path Yellow, STS
Path AIS, BER, Single error inject, Far End Block Error (FEBE)
- VT: VT LOP, VT Path Yellow, VT Path AIS, BER
- Alarm Type: Burst or continuous. External TTL event
trigger when alarm is activated.
- Random Bit Error Injection: 1.5 x 10-3 to
10-9 rate or single
- Bipolar Pulse Violation: 1.5 x 10-3 to 10-9 rate or single
|
| Editing |
| Transport and Path Overhead Byte Modification: All of
the overhead bytes, except B1-B3 and H1-H3
Pointer Control: Single positive and negative
pointer justification and NDF pointer changes to any value for both
SPE and VT |
| General |
Frame Detection
- STS-1: Detection based on A1, A2
- STS-3/12 (Option): Detection based on A1, A2, A2
|
|
|
Portable SONET Analyzer (
SONETest Transceiver )
| Optical Specifications (Typical) |
- OC-1/3 Tx Power Out: -10 dBm
- OC-12 Tx Standard Power Out: -8 dBm
- OC-12 Tx High Power Out: -4 dBm
- OC-1/3/12 Rx Sensitivity: -30 dBm
|
| Measurements |
SONET Alarms
- Section: B1 Code Errors, OOF (Out of Frame), LOF,
Frame pattern errors, LOS
- Line: B2 Code Errors, LOP, FEBE, AIS
- Path: B# Code Errors, AIS, Yellow, FEBE
Payload Parameters
- VT Path: BIP-2, AIS, Path Yellow, FEBE
- DS3 Payload: Parity and Frame errors, Bit
Errors, AIS, Idle and All Ones, X-Bit
- VT1.5 Payload: Bit Errors (PRBS or fixed word),
AIS, Yellow, CRC-6, Frame errors, LOF
- STS-3c Payload: Bit Errors
T-carrier Parameters
- DS3: BPV, Parity, Bit and Status parameters
- DS1: BPV, CRC, Bit and Status parameters
|
| Performance Statistics |
Parameters
- Section (B1): Total, Rate, ES, SES Total
- Line (B2): Total, Rate, ES, SES Total
- STS Path (B3): Total, Rate, ES, SES
- VT Path (BIP-2): Total, Rate, ES, SES Total
- Payload/DS3 (Bit and Parity): Rate, Total, ES,
SES
- Payload/3C (Bit Error): Rate, Total, ES
|
| Data Communications Channel |
- Section: D1-D3, 192 kb/s
- Line: D4-D12, 576 Kb/s
|
| Orderwire |
- Local and Express handset interface
|
| Remote Interfaces |
- RS-232C, GPIB, parallel printer ports, VT100
Terminal drivers
|
| Physical Information |
- Dimensions: 6" H x 14.4" W x
16.5" D (152mm x 366mm x 419mm)
- Weight: 22 lbs
|
| Options |
- ST-112-E3: All electrical
- ST-112-03: Up to OC-3
- ST-112-12: Up to OC-12 (std or high power)
- Type 560 connectors for STS-1/DS3
- Bantam Connectors for DS1
- Orderwire handset
- FC/PC, ST or SC optical connectors
- Rack Mount
|
|