Advanced Test Equipment Rentals spacer
Advanced Test Equipment Rentals
Request a Rental QuoteRequest a Sales QuoteRequest a Service QuoteContact Us
iso9001

spacer
  Home line Equipment line Manufacturers line Request line Contact Us line About Us line Events line Forms line Employment  
Home - Inspection
Panametrics 36DL Plus

Panametrics 36DL Plus 36DL Plus Ultrasonic Thickness Gage
  • Standard Measurement Mode:
    Time interval from a precision delay after the excitation pulse to the first echo.
  • Thru-Paint Echo-to-Echo Mode:
    Time interval between two successive backwall echoes for elimination of paint or coating using dual or single element transducers. Manual Mode or Automatic Mode.
  • Thickness Measurement Range:
    0.020-20 inches (0.5-500mm).
  • Material Velocity Range:
    0.0300-0.5511 inch/µS.(0.762-13.999mm/µS).
  • Manual Gain Adjust:
    Allows the gain to be manually increased or decreased in 1dB steps.
  • Automatic Probe Recognition:
    The 36DL PLUS automatically adjusts internal parameters and corrects for V-path.
  • Zero Compensation Mode:
    Provides zero offset compensation for temperature variations in the transducer material, and for transducer wear.
  • Alarm Mode:
    Programmable Hi-Low Alarm set points with audible and visual indicators.
  • File Structures:
    Data can be stored in 8 standard or custom application-specific file structures.
  • Reports:
    On-gage reporting of: Summary with statistics, Min/Max with locations, and File Comparison. On-screen comparison of current and previous readings.
  • Interface Program:
    16-bit or 32-bit Windows Interface Program compatible with Windows 3.x, 95 and NT.
  • Datalogger and RS-232:
    The 36DL PLUS identifies, stores, recalls,clears, and transmits thickness readings, waveform images, and gage setup information via the RS-232 Serial Port. Baud Rate, Word Length, Stop Bits, and Parity are adjustable from the keypad.
  • Maximum # of Stored Values:
    Up to 95,000 thickness readings and/or 4000 waveforms, or combination of both.
  • Stored Data Documentation:
    Each saved thickness reading or waveform is fully documented with measurement status flags and a setup number which identifies parameters such as velocity, transducer gain, etc.