3M / Photodyne 2260XFX Dual Wavelength Test Set
The Photodyne 2260XFX Dual Wavelength Test
Set tests 1300 and 1550 nm wavelengths simultaneously reducing measurement
time, inaccuracies due to connect/reconnect problems, and the cost of
making two measurements. The unit is easy-to-use
with two-button operation and features a large liquid crystal display
(LCD) showing both the wavelength and associated loss at all times. The
LCD panel also displays the dBm reference.
Features:
-
Simultaneous dual wavelength
measurement
-
2 KHz tone generation
-
55 dB dynamic range
-
Interchangeable connector adaptors
-
Rugged, lightweight design
-
User-friendly two-button operation
Benefits:
-
Saves time and money: fewer
connect/reconnect errors
-
Can be used with the 8000XG Fiber
Identifier
-
Powerful enough to test even the
longest links
-
Minimizes training; easy-to-learn,
easy-to-use
-
Dependable, even in the field
| Electrical
Specifications |
| Light
Source: |
Laser
diode |
| Detector
type: |
InGaAs |
Crosstalk
isolation
(typical): |
40
(dB) |
| Dynamic
range: |
+3
to -65 dBm |
| Wavelengths: |
1300 nm ±20 nm
1550 nm ±20 nm |
| Peak
output power: |
-10
dBm |
| Spectral
width: |
5
nm |
| Stability: |
±0
.05 dB @1h |
| Measurement
accuracy: |
±0
.25 dB |
| Laser
safety: |
Meets
class I laser safety CDRH |
| Source
modulation: |
2
KHz |
| Display
type: |
Custom
LCD |
|