Polytec OFV501
Polytec OFV501 Fiber Vibrometer

SPECIFICATIONS

Interferometer

General Data / Operating Parameters

  • Laser Type: Helium Neon
  • Laser Wavelength: 633 nm
  • Cavity Length: 205 mm
  • Laser Output Power / Classification: 2.3 mW / IIIa
  • System Output Power / Classification: < 1 mW / II

OFV-501 Fiber Optic, Single Point Interferometer

  • Range of Standoff Distances: 5 cm to 30 m
  • Length of Fiber Cable: 2 m (3 m)
  • Minimum Bending Radius: 50 mm

Optical Head for Use with Fiber Optic Interferometer

  • OFV-100 dimensions (L x Diam.): 4.3 x 2.25 cm (1.7 x 0.9")

OFV-3000 Controller Processor

General Data / Operating Parameters

  • Power Requirement: 100 / 110 / 220 / 240 VAC

Preamplifier and Tracking Filter Section

Tracking Filter Specifications

  • Track Range: 40 MHz ± 20 MHz
  • Range settings and associated maximum vibration frequencies:
    "OFF": 1.5 MHz max, depending on decoder range selected
    "FAST": 400 kHz max depending on target reflectivity
    "SLOW": 100 kHz max depending on target reflectivity

Velocity Decoder Specifications

Decoder Type Measurement Range Full Scale Output
(Peak to Peak)
Resolution Max. Signal Bandwidth
(3dB value)
OVD mm/s/V mm/s µm/s kHz
-01 1
5
25
125
1,000
20
100
500
2,500
20,000
0.5
0.6
0.8
1
2
35
150
150
150
150
-02 5
25
125
1,000
100
500
2,500
20,000
0.8
2
5
10
250
1,500
1,500
1,500
  • Output Swing: ± 10 Volts
  • Output Impedance: 100 Ohms

Low Pass Filter Specifications

  • Filter Type and Order: Bessel 3rd order
  • Selectable Cutoff Frequencies: 5 / 20 / 100 kHz

Displacement Decoder Section

Decoder Type Measurement Range Full Scale Output
(Peak to Peak)
Resolution Max. Signal Bandwidth
(3dB value)
|
|
|
OVD
-20
|
|
|
mm/V mm µm kHz
2
8
20
0.032
0.13
0.32
0.008
0.032
0.08
50
|
OVD
-10
|
80
320
1,280
5,120
1.3
5.2
20.5
82
0.32
1.3
5
20
50
  • Output Swing: ± 8 Volts
  • Output Impedance: 100 Ohms
  • Triggering: Manual triggering is possible using the RESET button on the front panel.  Synchronized triggering is possible using related BNC connector.  Slope: positive, min. signal level: 50 mVpp

Outputs

  • RF Out: Buffered return signal from interferometer.  BNC 40 MHz ± 32 MHz, 50 Ohms
  • Vel Out: Output voltage proportional to instantaneous velocity.  BNC ± 10 V full scale, 100 Ohms
  • Dspl Out: Output voltage proportional to displacement of target.  BNC ± 8 V full scale, 100 Ohms

Haefely
ECOMPACT4

Haefely Ecompact 4
CA Instruments
5001ix


California Instruments 5001ix
Voltech
PM6000

Voltech PM6000
IFI
T4026-40

IFI T4026-40

Teseq
NSG437
Varian 956 Porta Test
Solar
2654-1

Solar 2654-1
Terms & Conditions Privacy Notice Site Map Terms of Use
 