IEEE-488 Bus-Compatible Hipot Test System
- Safe, Fast, Efficient
- Fully programmable test parameters
- Digital display
- Performs an AC dielectric strength (Hipot) test concurrent with a ground
continuity test
- Applies a test potential of up to 5000 VAC at 50 milliamps (user programmable )
- Performs tests in full compliance with UL, VDE, BSI, IEC, CSA, and other test
standards
IEEE-488 BUS-compatible - enables data logging during each test, and
remote programming of:
- Test Voltage
- Test Time
- Voltage Ramp Rate
- Real Current Trip Point
- Total Current Trip Point
- Under Current Trip Point
Detects and indicates the following events:
- Test Ready (Security Chassis Ground Sensed)
- Test in Progress
- Test Passed
- Test Failed:
* Arcing
* Excessive Total Leakage Current
* Excessive Resistive Leakage Current
* Under Current
* Lack of adequate Chassis Ground
Superior Safety Features
- Visual and Audible alert indicating Hipot test in progress
- Low Current Security Chassis Ground Circuit (ensures Device Under Test has ground
connection of 0.5 ohm between chassis and power cord ground pin)
- Fast HV shutdown within 2 milliseconds of HV test automatically on test failure
or on command
Specifications
- Output Test Voltage*: 100 VAC - 5K VAC
- Output Voltage Ramp Time*: 50 V/sec to 5k V/sec
- Total Current Trip Point*: 50 mA (maximum)
- Real Current Trip Point*: 5 mA (maximum)
- Under Current Trip Point*: 5 mA (maximum)
- Test Time*: 1 sec - 100 sec
- Shutdown Time: 2 milliseconds
- Arc Detection: Arc duration 10µS or greater
- Ground Continuity: Low current ( 1.5 Amp @ 1.5V )
- Input Power Required: 115 / 230 VAC ± 10%, 47 - 63 Hz, 250 watts maximum
* User Programmable |