NSG1025 Available with CDN125 coupling clamp (shown below) or CDN300 3 Phase Coupler (not shown)

CDN125 - Capacitive Coupling Clamp
- Coupling clamp to IEC 1000-4-4 / 801-4
- For burst pulses and fast transients
- Injection into signal and data cables, plus AC line and DC power supply cables
|
|
Teseq / Schaffner NSG1025 & CDN125 Fast Transient Burst Generator
Features
- Conforms to IEC 801-4; IEC 1000-4-4
- Test voltages up to 4400V
- Burst frequencies up to 10KHz
- Single pulse capability
- Integrated coupling network
Specifications
| Pulse amplitude |
225V; 4400V (off-load) |
| Polarity |
Pos. or neg. selectable |
| Pulse rise time |
5ns ± 20% |
| Pulse width |
50ns ± 30% |
| Burst frequency f Burst |
2,5/5/10kHz ± 10% |
| Burst duration t Burst |
15ms ± 20% |
| Burst repetition t Rep |
300ms ± 20% |
| Generator impedance |
50ohm ± 20% (dynamic) |
| Coupling network |
as per IEC 801-4, built-in |
| Inputs/Outputs |
| IEC equipment socket for the instrument supply |
| 16A equipment plug for the test object supply |
| Test object connection; country-specific mains socket - UL |
| Gate function for Burst and 50Hz pulse: |
BNC, active 0 |
| Trig, function for single pulse: |
BNC, active 0, with LED |
| Pulse output: |
HV coaxial connector |
| Measurement output: |
BNC, 100:1 into 50 ohm |
|