Schaffner NSG 438 ESD Simulator System
Top Class ESD Simulation
The Schaffner NSG 438 ESD Simulator
System generates standard-conform discharge pulses of 200V to 30kV, in
both air discharge and contact discharge operation.
The full range of parameter setting possibilities for polarity, pulse repetition, counter functions, breakdown detection, etc.,
remains fully available, all the way up to the maximum
discharge voltage setting.
Being well-balanced and pistol-shaped ensures that the Schaffner NSG 435 is natural and
comfortable in use. The control elements and display can always be seen
by the operator, current operating conditions are constantly displayed.
The NSG 438 by Schaffner fulfills the
requirements of all known ESD standards. The basic model is type approved and calibrated in conformity with IEC/EN 61000-4-2. By
adding appropriate network modules, other standards
can be accommodated such as ISO 10605, which calls for elevated pulse
voltages of up to 25kV, as well as various MIL
standards. Other applications can be accommodated through the use of special networks.
Industry specialists are currently working
on a revision of the ESD standards and have sent recommendations
for consideration to ANSI and the IEC. The proposals concern both, a more precise definition of the calibration methods, in addition
to a tightening of the specifications pertaining to
the pulse parameters themselves. The Schaffner NSG 438 system already
meets these proposed requirements.
Features:
-
Air and contact discharge 0.2kV to 30 kV
-
Touch panel display controlled
-
Battery powered
-
Compliant with all known standards (IEC, ANSI, SAE,
ISO, Mil etc)
-
Interchangeable network modules
-
Discharge detector
Technical specifications
| Instrument
type |
ESD
generator consisting of a base unit, discharge pistol, mains adapter
and battery charging unit |
| Power
supply |
Battery
or mains operation (100 - 240Vac) |
| Base
unit |
High voltage generator;
microprocessor-based controller, optical PC interface, interlock,
input/outputs for end of test, EUT-fault |
| Discharge
pistol |
Operating
unit with touch-sensitive display panel, exchangeable test probes and
networks, trigger button |
| Pulse
specifications |
IEC/EN 61000-4-2 with standard network
(150pF/330Ω)
ISO 10605 with network INA 4381 (150pF/2kΩ) and INA 4382 (330pF/2kΩ)
Others according to requirements |
| Discharge
voltage |
200V
to 30kV for air discharge and contact discharge, programmable in 100V
steps |
| Pulse
polarity |
Positive,
negative automatic switching |
| Pulse
repetition |
Single
pulse; continuous at 0.5, 1, 5, 10, 20 & 25Hz; statistical
distribution in 2 modes |
| Voltage
measurement |
Dynamic
discharge voltage measurement in air discharge mode |
| Discharge
detection |
With
adjustable threshold |
| Pulse
counter |
Forwards pulse counter or backwards as a
preset counter, up to 9999 pulses |
| Pulse
triggering |
Trigger-button,
or remote control signal |
| Touch-panel
display |
Back-lit
display with touch-sensitive control surfaces and a virtual thumbweel,
used to monitor and set up all the instrument's functions: Discharge
voltage, breakdown voltage, type of discharge, polarity, repetition
rate, counter/preset counter, memory, language, instrument status,
detector threshold, etc. |
| Test
program memory |
Preset test data to IEC, ISO or other
standards.
Store and recall of 8 complete user defined tests |
| Environmental
conditions |
5
to 40°C (40 to 105°F); 20 to 80% rh (non condensing); 68 to 106kPa |
| Certification |
To
EN 61326-1, EN 61000-6-2, EN 61000-6-3 |
View Schaffner INA Custom Networks |