Schaffner NSG2050

Schaffner NSG2050 w/CDN131

The above NSG2050 High Energy Pulse Generator (top unit in picture)  includes a PNW2050 1.2/50-8/20 Impulse Network module and is shown with an optional CDN 131 Single-Phase Pulse Coupling Network (bottom unit).

CDN 131 Single-Phase Pulse Coupling Network

CDN 133 3-Phase Coupling Network

Schaffner NSG2050 High Energy Pulse Generator System

The NSG2050 is intended for executing interference immunity tests with surge pulses as called for in IEC 801-5 and various derivatives such as IEC 1000-4-5, EN 55101-5, IEC 384-14, ANSI/IEEE C62.41, CCITT, FCC Part 68, Bellcore TR-NWT-001089, etc.

NSG2050 PULSE GENERATOR (top unit in picture)

  • Pulse Voltage: 6.6 kV max
  • Repetition Rate: depends on the PNW
  • Phase positioning: synchronous from 0-359° or asynchronous
  • Polarity: positive, negative or alternating
  • Internal Impedance: depends on the PNW
  • Pulse Rise Time: depends on the PNW
  • Pulse Width: depends on the PNW
  • Remote Control Input: RS 232 port on the rear panel

PULSE NETWORKS, PNW

PNW 2050 (installed in top unit)
Produces the following pulses to satisfy the requirements of the standards: IEC 1000-4-5 (IEC801-5) / EN 61000-4-5 / IEEE C62.41 / IEEE 587 / etc.

Hybrid Pulse: 1.2/50 µs (open-circuit) 200 V to 6.6 kV;  8/20 µs (short-circuit) at up to 3.3 kA

  • Pulse Form: 1.2/50 µs (open-circuit); 8/20 µs (short-circuit into 2 ohm impedance)
  • Voltage: 200 V to 6600 V adjustable in 10 V steps
  • Short-Circuit Current: 100 A to 3300 A into 2 ohm impedance; 16.6 A to 550 A into 12 ohm impedance
  • Impedance: 2 ohm, 12 ohm
  • Polarity: P (positive), N (negative), A (alternating)
  • Pulse Outputs: Earth-free (floating)
  • Repetition: 10 s to 10000 s
  • Number of pulses: 1 to 9999

PNW 2051
Produces the following pulses to satisfy the requirements of the standards: IEC 1000-4-5 (IEC801-5) / CCITT / NF C98-010 / etc.

Telecom Pulse: 0.5/700 µs (open-circuit) 200 V to 6.6 kV.  10/700 µs (short-circuit) 200 V to 6.6 kV

  • Pulse Form: 0.5/700 µs (open-circuit); 10/700 µs (short-circuit)
  • Voltage: 200 V to 6600 V adjustable in 10 V steps
  • Short-Circuit Current: 13.3A to 440 A into 15ohm impedance; 5 A to 165 A into 40 ohm impedance
  • Impedance: 15 ohm, 40 ohm
  • Polarity: P (positive), N (negative), A (alternating)
  • Pulse Outputs: Earth-free (floating)
  • Repetition: 15 s to 10000 s
  • Number of pulses: 1 to 9999

PNW 2052
Produces the following pulses to satisfy the requirements of the standards: IEEE C62.41 / C 1000-4-12 / etc.

Ring-wave 0.5 µs/100 kHz (open circuit) 200 V to 6.6 kV

  • Pulse Form: 0.5 µs/100 kHz (open-circuit)
  • Voltage: 200 V to 6600 V adjustable in 10 V steps
  • Short-Circuit Current:
    16.6 A to 550 A into 12 ohm impedance
    6.6 A to 220 A into 30 ohm impedance
    1 A to 33 A into 200 ohm impedance
  • Impedance: 12 ohm, 30 ohm, 200 ohm
  • Polarity: P (positive), N (negative), A (alternating)
  • Pulse Outputs: Earth-free (floating)
  • Repetition: 10 s to 10000 s
  • Number of pulses: 1 to 9999

PNW 2055
Produces the following pulses to satisfy the requirements of the standards: IEC 1000-4-5 (IEC801-5)/ EN 61000-4-5 / IEEE C62.41 / etc.

Hybrid pulse 1.2/50 µs (open circuit) 200 V to 4.4 kV; 8/20 µs (short-circuit) at up to 2.2 kA with built in Coupler

  • Pulse Form: 1.2/50 µs (open circuit); 8/20 µs (short-circuit into 2 ohm impedance)
  • Voltage: 200 V to 4400 V adjustable in 10 V steps
  • Short-Circuit Current:
    100 A to 2200 A into 2 ohm impedance
    16.6 A to 366.6 A into 12 ohm  impedance
  • Impedance: 2 ohm, 12 ohm
  • Polarity: P (positive), N (negative), A (alternating)
  • Repetition: 10 s to 10000 s
  • Number of pulses: 1 to 9999
  • Phasing: Asynchronous, synchronous over 0 to 359°
  • Technical data concerning the built-in CDN in the PNW 2055
    • Coupling Modes:
      2 ohm: L -> N
      12 ohm: L -> PE, N -> PE, L+N -> PE
      * The pulses can only be coupled into the mains feed via the internal, single-phase coupling network (CDN)
    • Number of phases: 1
    • Voltage, 50/60 Hz: 20...230 Veff.
    • Current: 16A, continuous

Please contact us for more information on the Schaffner NSG2050


Agilent
E4437B

Agilent E4437B
Yokogawa
WT1600B


Yokogawa WT1600B
Anritsu
MS2026A

Anritsu MS2026a
Megger
DLRO-200-115

Megger DLRO-200-115

Teseq
NSG437
Varian 956 Porta Test
Solar
7054-1

Chauvin Arnoux 6121
Chroma
63209
Chroma 63209
Privacy Notice Site Map Terms of Use
Copyright © 1996-2007  |  Advanced Test Equipment Rentals  |  All Rights Reserved