Schaffner NSG 500C/506C EMC Test System for Automotive Electronics
The
NSG500C unit contains two generators in a compact form; one for the microsecond pulse
range (pulses 1 and 2) and the other for the fast pulse bursts in the nanosecond range
(pulses 3a and 3b), together with a common control section.
The rise time, pulse width and amplitude of the pulses 1 and 2 can be varied
within wide limits. Facilities are provided to connect external impedances to match
the generator to the conditions such as are to be found in a vehicle's supply system.
The pulse bursts, 3a and 3b, can be set in amplitude and polarity to suit the
test specification.
The front panel is equipped with a presettable counter which enables automatic
tests to be carried out for a predetermined time or number of cycles. Triggering can
be set for manual or external operation and a trigger output is provided to drive an
oscilloscope.
Dampening of the interference pulses by the supply source is prevented by a
built-in network.
Schaffner NSG500C
- Pulse 1
* Peak Voltage: -30 to -300 V
* Risetime: 1 / 2 / 3 / 4 µs
* Pulse width: 50 / 200 µs / 2 ms
* Repetition rate: 0.5 / 5 s
* Selectable Battery Off time: 200 ms
* Source Impedance: 4 / 10 / 20 / 30 / 40 / 50 ohm
- Pulse 2
* Peak Voltage: +30 to +300 V
* Risetime: 1 / 2 / 3 / 4 µs
* Pulse width: 50 / 200 µs / 2 ms
* Repetition rate: 0.5 / 5 s
* Selectable Battery Off time: 200 ms
* Source Impedance: 4 / 10 / 20 / 30 / 40 / 50 ohm
- Pulses 3a/3b
* Peak Voltage: +-40 to +-200 V
* Risetime: 5 ns
* Pulse width: 100 ns
* Repetition rate: 100 µs
* Burst Length: 10 ms
* Time between burst groups: 90 ms
* Source Impedance: 50 ohm
- Operating Modes:
* Single pulses or bursts
* Manual or external triggering
* Repetitive pulses or bursts
* Repetition frequency according to pulse type
- Test Duration: Settable with built-in preselection counter for defined time or
number of pulses: 1 - 999999 secs or 1 - 999999 pulses
- External Trigger: TTL input. 0=true; also suitable for a momentary push-button
- CRO Trigger: trigger output + 10V, Tr 1.5µs
- DUT Supply Voltage: 12 - 30 Vdc
- DUT Supply Current: 25A max. (circuit breaker)
- DUT Connection: Universal connector sockets
- Weight: 16 - 20 kg (35-44 lbs) approx.
Applicable Standards:
- ISO 12V; ISO DP 7637/1
- ISO 24V; ISO DP 7637/2
- SAE J 1113
- DIN 40839-T3
Schaffner NSG506C
The two-part Generator, Type NSG506C, has been designed as an auxiliary
unit for the NSG500C and enables the production of high energy pulses (pulses 5 and 7).
- Pulse 5
* Peak Voltage: 0 to +200 V
* Risetime: 0.1 / > 5 <10 ms
* Pulse width: 40 / 100 / 150 / 200 / 300 / 350 / 400 / 500 ms
* Source Impedance: 0.5 to 5.5 ohm
- Pulse 7
* Peak Voltage: 0 to -200 V
* Risetime: 0.1 / > 5 <10 ms
* Pulse width: 40 / 100 / 150 / 200 / 300 / 350 / 400 / 500 ms
* Source Impedance: 8.5 to 13.5 ohm
- Storage Capacitor: 47 000µF
- Energy: 940 Joule max.
- Pulse Triggering: controlled via the NSG500C; manual; external trigger; automatic
(pulse interval 5 secs)
- Pulse Interval: 5 secs min.
- Weight: 36 kg approx. (79 lbs) (part 1 and 2)
|