Sigma Systems M600MM Chamber
Model M600MM is supplied with a castered
stand and is
Cascade refrigerated.
Operating Ranges °C |
High limit |
Low limit |
|
200 |
-65 L-CO2
-100 L-N2 |
Performance °C
(Center 70% of range) |
Ramp down
°C per minute |
Ramp up
°C per minute |
|
1.6
(Refrigeration only)
18 (with Boost option) |
8 (Refer off)
6 (Refer on) |
Cooling rate
Cryogenic rates are highly dependent upon coolant
type (LN2 or LC02), pressure, and
quality. |
Chamber Size |
Workspace |
Exterior |
Volume
Feet3
(Liters) |
H x W x D
Inches
(Centimeters) |
H x W x D
Inches
(Centimeters) |
20.7
(587) |
34.6 x 35.0 x 29.6
(87.9 x 88.9 x 75.2) |
46.1 x 40.0 x 46.3
(117.1 x 101.6 x 117.6) |
|