Solar 7054-1 Spike Generator
The Model 7054-1 Spike Generator was
especially designed for screen room use in
applying high voltage transients at power line
inputs to electronic equipment. The adjustable
amplitude makes it possible to determine
the threshold of susceptibility to spikes
appearing on the power line. The Model 7054-1
may be used for performing tests per
Method CS06 of MIL-STD-462, Method 5006.1 of
MIL-STD-826A, RTCA D0160D (with impedance
matching transformer) various missile specifications
and others.
- Provides output levels from 10 volts to more
than 600 volts into 5 ohms or less. Delivers
more than 300 kw peak into 0.5 ohm load.
- Adjustable pulse position on a.c. lines relates
the transient susceptibility to real time aspects
of digital systems.
- Single pulse feature for controlled isolation of
transient effects.
- Output terminals for series or parallel
injection.
SPECIFICATIONS
- Spike Amplitude: Continuously adjustable from
10
volts to over 600 volts peak.
- Repetition Rate: Continuously adjustable from
0.8
to 10 p.p.s.
- Rise Time: Less than 1.0 microsecond, into 5 ohm
resistive load.
- Spike Duration: Output falls to zero in
approximately
10 microseconds.
- Spike Shape: See curve. Similar to Figure 19 of
MIL-STD-462
- Phase Adjustment: Spike position adjustable
from 0°
to 360° periodically on 50, 60 or 400 Hz
sine wave.
- Internal Impedance: Less than 0.5 ohm.
- Output Power: More than 300 kw peak into
0.5 ohm load.
- Power Current in Series Injection
- Mode:
Handles up to 25 amperes of current at power
frequencies.
- Power Requirements: 115 volts 60 Hz,
1.6 amperes. (230
volts 50 Hz, 0.8 ampere
available. )
- Size:Standard rack panel: 7" high, 19" wide, 12.75"
deep.
(17.78 cm x 48.26 cm x 32.38 cm.)
|