NTSC Waveform/Vector Monitor
- Dual Filter/Simultaneous Display
- Two Instruments in One
- SCH Phase and Color Framing
- R-Y (V-Axis) Mode
- RGB/YRGB Mode
- Remote Control Capability
- Line and field selection for VITS / ITS monitoring
- Comprehensive signal monitoring
CHARACTERISTICS
WAVEFORM MODE ( VERTICAL DEFLECTION SYSTEM )
- Deflection Factor: 1V input for 140 IRE display
- Gain Ranges: Input signals between 0.7 V and 2 V can be adjusted to 140 IRE
Frequency Response
- Flat: ±2% from 50 kHz to 6 MHz
- IRE: Conforms to IEEE Standard 205
- CHROMA: Response at 3.58 MHz does not vary between FLAT and CHROMA by more than
1%
Pix Mon Output
- Frequency Response: 50 kHz to 6 MHz
- Output Impedance: 75 ohms
Calibrator Signal
- Frequency: 100 kHz
- Amplitude: 1 V
WAVEFORM MODE ( HORIZONTAL DEFLECTION SYSTEM )
- Sweep: Sweep will occur in all Horizontal mode settings with or without
synchronization
- 1FLD sweep repetition rate
- 2FLD sweep repetition rate
- 1H sweep repetition rate
- 2H sweep repetition rate
VECTOR MODE
- Chrominance Bandwidth:
Upper: -3 dB Point Fsc +500 kHz, ±100 kHz
Lower: -3 dB Point Fsc -500 kHz, ±100 kHz
|