Advanced Test Equipment Rentals spacer
Advanced Test Equipment Rentals
Request a Rental QuoteRequest a Sales QuoteRequest a Service QuoteContact Us
iso9001

spacer
  Home line Equipment line Manufacturers line Request line Contact Us line About Us line Events line Forms line Employment  
Home - Oscilloscopes
Tektronix TDS460
Tektronix TDS460

Display

  • Waveform Style - Dots or vectors. Infinite and variable persistence from 250 ms to 10s.
  • Gray Scaling
  • Update Rate - 200 ea. 500 point waveforms per sec with infinite persistence mode selected.
  • Graticules - Full, grid, cross hair, frame
  • Format - YT and XY
  • VGA Out - Drives VGA display monitors.
  • Zoom -  The zoom feature allows waveforms to be expanded, compressed and positioned in both vertical and horizontal axes.

Measurement System

Automatic Waveform Measurements

Period Frequency
High Low
+ Width - Width
Maximum Minimum
Rise Fall
Peak to Peak Amplitude
+ Duty Cycle - Duty Cycle
+ Overshoot - Overshoot
Propagation Delay Burst Width
Mean Cycle Mean
RMS Cycle RMS
Area Cycle Area

Phase

 
Continuous update of up to four measurements on any combination of waveforms.
Digitizing Oscilloscope

Signal Acquisition System

  • Bandwidth - 350 MHz
  • Channels - 4
  • Digitizers - 4
  • Sample Rate - 100 MS/s on all channels
  • Sensitivity - 1 mV to 10 V/div
  • Position Range - ± 5 Divisions
  • Vertical Resolution - 8-bits (256 levels over 10.24 vertical divisions).
  • Analog Bandwidth Selections - 20 MHz, 100 MHz, and full.
  • Input Coupling - AC, DC, or GND
  • Input Impedance Selections - 1 M ohm in parallel with 15 pF, or 50 ohms (AC and DC coupling).
  • Maximum Input Voltage - ± 400 V (DC + peak AC).

Acquisition Modes

  • Peak Detect
  • Sample
  • Envelope
  • Average
  • Hi-Res

Time Base System

  • Time Bases - Main, Delayed
  • Time/Division Range - 1 ns to 20 s/div
  • Record Length (real time and equivalent time) - Sample points per channel:  500 to 15,0000, Opt. 1 offers 60,000 points.
  • Pre-Trigger Position - Selectable from 0 to 100% of record.

Triggering System

  • Triggers - Main, Delayed.
  • Main Trigger Modes - Auto, Normal, Single Sequence.
  • Delayed Trigger - Delayed by time or events.
  • Time Delay Range - 0 ns to 20 s.
  • Events Delay Range - 2 to 10,000,000 events.
  • Video Trigger Types - NTSC, PAL, SECAM, and Custom; TV Field, field 2 or both.

Agilent
E4437B

Agilent E4437B
Yokogawa
WT1600B


Yokogawa WT1600B
Anritsu
MS2026A

Anritsu MS2026a
Megger
DLRO-200-115

Megger DLRO-200-115

Teseq
NSG437
Varian 956 Porta Test
Solar
7054-1

Chauvin Arnoux 6121
Chroma
63209
Chroma 63209
Privacy Notice Site Map Terms of Use
Copyright © 1996-2007  |  Advanced Test Equipment Rentals  |  All Rights Reserved