EMC Compliance Tests:
| Generic
Standards: |
| EN 50082-1 |
Generic immunity standard - part 1:
residential, commercial and light industry |
| EN 50082-2 |
Generic immunity standard - part 2:
industrial environment |
| Product Standard: |
| EN 50090 |
Home and building electronic systems (HBES) |
| EN 50130 |
Alarm systems including fire, intruder
and personal alarms |
| EN 55011 |
Industrial scientific and medical
(ISM) equipment (CISPR 11) |
| EN 55103 |
Professional audio, video,
audio-visual and entertainment lighting control apparatus |
| EN 55104 |
Household appliances, tools and
similar apparatus |
| EN 60601 |
Medical electrical equipment |
| EN 60945 |
Maritime navigation and radio
communication equipment and systems |
| EN 60947 |
Low voltage switchgear and control
gear |
| EN 61131 |
Programmable controllers |
| EN 61800 |
Adjustable speed electrical power
drive systems |
|
|
Schaffner Best Plus Conducted Immunity Test System
Specifications:
Burst per IEC61000-4-4 / EN61000-4-4
- Pulse Form: 5/50 ns
- Pulse Amplitude: 200 - 2200 V
- Pulse Frequency: 1 - 100 kHz
- Polarity: pos/neg
- Pulse/Burst: 1 - 75
- Burst Period: 100 ms - 99 s
- Coupling: L<>Ref. GND
N<>Ref. GND
PE<>Ref. GND
L+N<>Ref. GND
Coupling Clamp
Surge per IEC61000-4-5 / EN61000-4-5
- Pulse Form: 1.2/50 µs open-circuit, 8/20 µs
short-circuit
- Pulse Amplitude: 200 - 2200 V
- Impedance: 2/12 ohms
- Polarity: pos/neg
- Pulse Repetition: 10 s min, 600 s max
- Coupling:
L<>N
L<>PE / N<>PE
L+N<>PE
ESD per IEC61000-4-2 / EN61000-4-2
- Discharge Voltage: 8.8 kV air, 6.6 kV contact
- Pulse Rise-Time: 0.7 - 1 ns
- Network: 150 pF/330 ohms
- Polarity: pos/neg
- Pulse Repetition: Single pulse repetitive up to 25 Hz,
pre-settable counter, remote triggering
Power Quality (Dips & Interrupts) per
IEC61000-4-11 / EN61000-4-11
- Mains Drop-Out: 10 ms - 5 s
- Voltage Dip: 70% Vn for 10 ms - 5 s
- Phase Angle: 0 - 359°
- Power Up Current: 500 Amps
|