Performance
Specifications:
AC/DC VOLTAGE and AC/DC CURRENT (True RMS)
Accuracy: (Voltage and Current)
DC & 40 Hz to 5 kHz: ± 0.1% of reading ± 6 digits
5 kHz to 15 kHz: ± 0.5% of reading ± 6 digits
15 kHz to 20 kHz: ± 0.75% of reading ± 6 digits useable to 50
kHz with typically 1% error per 10 kHz
WATTS
Accuracy: 25°C ± 5°C, 1 year
DC & 40 Hz to 5 kHz: ± 0.25% of reading ± 6 digits
5 kHz to 10 kHz: ± 0.5% of reading ± 0.5% of range
10 kHz to 20 kHz: ± 1% of reading ± 1% of range (2A range only)
20 kHz to 50 kHz: additional ± 1% per 10 kHz above 20 kHz |
|
20 kHz AC Power Meter
Specifications:
- Displays dual 4½ digit
- Load Connection: 4 Terminal heavy duty binding posts
Range/Resolution:
True RMS
Voltage |
True RMS Current |
| .2000A |
2.000A |
20.00A |
| 150.00V |
30.00W |
300.0W |
3000W |
| 300.0V |
60.00W |
600.0W |
6000W |
| 600.0V |
120.00W |
1200.0W |
12000W |
| |
True WATTS |
|