The 2301 single phase power analyzer provides high accuracy power measurements. It features 4 ½ (20,000 counts) tri-mode V-A-W information displays.
| Accuracy |
(Voltage and Current True RMS) |
| DC & 20 Hz to 5 KHz |
± 0.1% of reading ± 6 counts |
| 5 KHz to 10 KHz |
± 0.5% of reading ± 6 counts |
| 10 KHz to 20 KHz |
± 0.75% of rdg ± 6 counts - useable to 50 KHz with typically 0.75% error per 10 KHz |
| Maximum Input |
1000 VDC or RMS AC, 3000 V pk/pk |
| Displays |
4 ½ Digit (20,000 counts) 7 segment LEDs |
| Watts Accuracy |
25 °C ± 5°C, 1 year |
| DC & 20 Hz to 5 KHz |
±0.25% of reading ± 6 counts |
| 5 KHz to 10 KHz |
± 0.5% of reading ± 0.5% of range |
| 10 KHz to 20 KHz |
± 0.75% of reading ± 0.75% of range |
| 20 KHz to 50 KHz |
add 0.75% per 10 KHz above 20 KHz |
| Power Factor Response |
Unity (1.000) to zero (0.000) |