- Voltage Range: 0 - 60VDC
- Max. Load Voltage: 50VDC
- Min Load Voltage 3 VDC
- Meter Accuracy +2% Full Scale
- Protection Circuits: Electronic circuit limits power
dissipation to 750W. Load shuts down in the event of an overvoltage.
Thermal breakers shut off load in the event of an overtemperature
condition. Reverse diode across bus bars protect against reverse
polarity.
- Current signal output: voltage proportional to current
is provided. 1 millivolt per amp, ±1%
- Operating temperature range: 0 - 40°C
|