Standard Kit Includes:
- 5 - 10ft black voltage leads
- 5 - black alligator clips
- 12 color-coded rings
- USB cable
- NiMH battery
- 110/240V power adapter with US power cord
- DataView software
- Large classic tool bag
- Soft carrying pouch
- User manual
Optional Probes and Accessories:
- 4 x 24" AmpFlex 193-24-BK (6500A) sensors
- 4 x 36" AmpFlex 193-36-BK (6500A) sensors
- 3 x MN193-BK (6A/120A)
- 4 x MN93-BK (240A) probes
- 4 x SR193-BK (1200A) probes
Similar How-To-Videos
|
|
3-Phase Power Quality Analyzer
The AEMC 8335 PowerPad 3-Phase Power Quality Analyzer is easy-to-use, compact and shock-resistant. It is intended for technicians and engineers to measure and carry out diagnostic work and power quality work on one, two or three phase low voltage networks.
The AEMC 8335 PowerPad 2GB of memory is conveniently partitioned to let you store four different types of data, synchronized or independent of each other. You can store up to 50 screen snapshots, up to 300 captured transients that contain four cycles for each active input, and 10,000 alarm events from up to 40 different parameters. You can also record trend data for days, weeks or even months.
AEMC 8335 Applications:
- Verification of power distribution circuits
- Measurement and recording of power system quality (kW, VA, VAR)
- Energy metering (kVAh, VARh, kWh)
- In plant troubleshooting of power distribution panels and individual machinery
- Monitor pad mount transformers
- Determine harmonic problems originating from source or load
- Monitor phase unbalances
- Determine transformer K-Factor
AEMC 8335 Features:
- Measurement of TRMS voltages up to 1000Vrms AC/DC for two, three, four or five-wire systems
- Measurement of TRMS currents up to 6500Arms (sensor dependant)
- Measurement of DC current up to 1400ADC (with MR193 probe)
- Frequency measurement (40 to 69Hz systems)
- Direct measurement of neutral current for WYE configurations
- Record and display trend data as fast as once per second for one month for up to 25 variables.
- Transient detection on all V and I inputs
- Inrush current
- Calculation of Crest Factors for current and voltage
- Calculation of the K Factor for transformers
- Calculation of short-term flicker for voltage
- Calculation of the phase unbalance for voltage and current (3 phase only)
- Measurement of harmonic angles and rates (referenced to the fundamental or RMS value) for voltage, current or power, up to 50th harmonic
- Display of harmonic sequencing and direction and calculation of overall harmonics
- Real time display of Phasor diagrams including values and phase angles
- Monitoring of the average value of any parameter, calculated over a period running from 1 sec to 2 hrs
- Measurement of active, reactive and apparent power per phase and their respective sum total
- Calculation of power factor, displacement power factor and tangent factor
- Recording, time stamping and characterization of disturbance (swells, sags and interruptions, exceedence of power and harmonic thresholds)
- 2GB internal memory
- DataView software included
|