Advanced Test Equipment Rentals spacer
Advanced Test Equipment Rentals
Request a Rental QuoteRequest a Sales QuoteRequest a Service QuoteContact Us
iso9001

spacer
  Home line Equipment line Manufacturers line Request line Contact Us line About Us line Events line Forms line Employment  
Home - Network Analyzers
Anritsu MS2026A

Anritsu MS2026A Anritsu MS2026A VNA Master

VNA Master MS2026A is the most ultra-portableVNAs on the market. It is designed to make accurate vector corrected 1-Port and 1-path 2-Port magnitude and phase measurements from 2 MHz to 6 GHz (MS2026A). VNA Master's light weight(6.4lbs) and three hour battery life time provide you with the flexibility needed to make VNA measurements anywhere.

PERFORMANCE SPECIFICATIONS

Frequency

  • Frequency Range: 2 to 6000 MHz
  • Frequency Accuracy: 25 ppm
  • Frequency Resolution: 10 kHz
  • Data Points: Low, Medium, High (137/275/551)
  • Interference Immunity:
  • On-Channel: +17 dBm
  • On-Frequency: +10 dBm (RF Out), +30 dBc RF In
  • 1-Port Power: High: 0 dBm (typical)
  • 2-Port Power: High: 0 dBm (typical) Low: –35 dBm (typical)
  • Corrected Directivity: 42 dB (2 MHz to 6 GHz)
  • 1-Port Accuracy: = <0.8 + |20 log(1 ±10-EΔ/20)| dB, typical EΔ = Directivity – Measured Return Loss
  • System Dynamic Range:
    • 80 dB, 2 MHz to 3 GHz
    • 70 dB, >3 GHz to 5.5 GHz
    • 65 dB, >5.5 GHz to 6 GHz
Return Loss
Range: 0 to 60 dB
Resolution: 0.01 dB

VSWR
Range: 1 to 65
Resolution: 0.01

Cable Loss
Range: 0 to 30 dB
Resolution: 0.01 dB

1-Port Phase
Range: –180° to +180°
Resolution: 0.01°

Smith Chart
Resolution: 0.01

2-Port Gain
Range: –120 to 100 dB
Resolution: 0.01 dB

2-Port Phase
Range: –180° to +180°
Resolution: 0.01°

Distance-to-Fault (DTF)
  • Fault Resolution (meters): (1.5 x 108 x vp)/ΔF vp is the propagation constant and ΔF is F2-F1 in Hz
  • Horizontal Range (meters): 0 to (data points-1) x Fault Resolution to a maximum of 1500m (4921 ft) where datapoints = 137/275/551
  • Vertical Range (Return Loss): 0 to 60 dB
  • Vertical Range (VSWR): 1 to 65

RF Power Monitor (Option 5):
Display Range: –80 to +80 dBm (10 pW to 100 kW)
Detector Range: –40 to +20 dBm (100 nW to 100 mW)
Offset Range: 0 to +60 dB
Resolution: 0.1 dB or 0.1 W
Accuracy: ±1 dB maximum for >–40 dBm using 560-7N50B

Bias T (Option 10):
Voltage/Current: +12 V, 250 or 500 mA steady state
+15 V, 250 or 500 mA steady state
+18 V, 350 mA steady state
+21 V, 300 mA steady state
+24 V, 250 mA steady state

GPS Receiver (Option 31) GPS Location Indicator Latitude, Longitude, Altitude and UTC on Display

GENERAL SPECIFICATIONS
  • Languages Built-in English, Spanish, Italian, French, German, Japanese, Korean, and Chinese. Can also customize two additional languages using Master Software Tools.
  • Memory
  • Internal memory provides for the storage and recall of more than 1000 traces and setups. The contents of the internal memory can be copied to and from a removable Compact Flash Card.
  • Markers 6 markers (Delta marker, peak search, valley search) and Marker Table.
  • Traces View Trace, Memory, Trace-Memory, Trace + Memory, Trace and Memory
  • Limit Lines Upper and Lower Limit. Each upper and lower limit can consist of between one and forty segments.

Please contact us for more information on the Anritsu MS2026AA

Agilent
E4437B

Agilent E4437B
Yokogawa
WT1600B


Yokogawa WT1600B
Anritsu
MS2026A

Anritsu MS2026a
Megger
DLRO-200-115

Megger DLRO-200-115

Teseq
NSG437
Varian 956 Porta Test
Solar
7054-1

Chauvin Arnoux 6121
Chroma
63209
Chroma 63209
Privacy Notice Site Map Terms of Use
Copyright © 1996-2007  |  Advanced Test Equipment Rentals  |  All Rights Reserved