Fluke 810 Vibration Tester
Troubleshooting motors or other mechanical problems just found the ultimate solution- the Fluke 810 Vibration Tester. Vibration analysis is a simple solution to find answers in a complex mechanical troubleshoot and it's now an affordable rental that offers fast answers to current problems as well as a great tool for preventative maintenance. Advanced Test Equipment Rentals offers same-day shipping to alleviate interruptions in production. Contact us now if you need prompt assistance.
This Fluke vibration anlyzer utilizes a long history of data collection and analysis in its algorithms to offer fault detection on first measurement. No history of measurement is required. The diagnostic tools provide severity and repair recommendations, helping new users make critical decisions without the usual time and cost associated with technician troubleshooting.
Misalignment, unbalance, looseness, bearings, and other common fault determinations on motors, chain drives, gearboxes, belts, blowers, fans, propeller pumps, sliding vane pumps, screw pumps, rotary gear/lobe/thread pumps, piston compressors, centrifugal compressors, screw compressors, spindles, and closed couples machines is an easy diagnosis with the Fluke 810 Vibration Tester.
A laser tachometer measures accurate rotational speeds between 200 rpm and 12000 rpm. Vibrational measurement time is greatly reduced (by 2/3) with a tri-axial accelerometer over a single-axis accelerometer. This unit even connects to a PC. The diagnostics are offered in plain-text, repair details, spectral analysis, cited peaks, and fault severity (slight, moderate, serious, extreme).
Fluke 810 Electrical Specifications
| Ranging |
Automatic |
| A/D converter |
4 Channel, 24 bit |
| Usable bandwidth |
2 Hz to 20 kHz |
| Sampling |
51.2 Hz |
| Digital signal processing functions |
Automatically configured anti-alias filter, high-pass filter, decimation, overlapping, windowing, FFT, and averaging |
| Sampling rate |
2.5 kHz to 50 kHz |
| Dynamic range |
128 dB |
| Signal to noise ratio |
100 dB |
| FFT resolution |
800 lines |
| Spectral windows |
Hanning |
| Frequency units |
Hz, orders, cpm |
| Amplitude units |
in/sec, mm/sec, VdB |
| Non-volatile memory |
SD micro memory card, 2 GB internal + user accessible slot for additional storage |
|