Advanced Test Equipment Rentals spacer
Advanced Test Equipment Rentals
Request a Rental QuoteRequest a Sales QuoteRequest a Service QuoteContact Us
iso9001

spacer
  Home line Equipment line Manufacturers line Request line Contact Us line About Us line Events line Forms line Employment  
Home - Calibrators
Gilian Gilibrator
Gilian Gilibrator Sensidyne / Gilian Gilibrator Calibrator
Primary Standard for the Calibration of Air Sampling Equipment

The Gilibrator System from Gilian is an easy to use Primary Standard for the calibration of Air Sampling equipment. This unique system features 3 interchangeable flow cells that incorporate twist on/off mounting and a micro-processor control unit.Individual flow cells provide consistent pulsation free bubbles and the built in infrared sensors activate instantaneously to indicate the flow readouts on the Control Units LCD display. The 3 Flow Cell ranges are: High (2-30 LPM) Standard (20cc-6 LPM) and Low (2-250 cc/min.).The control unit also offers useful microprocessor functions that include Auto-Averaging of multiple flow readings and a Flow Delete function that will subtract false readings from the average and reset back to the previous value.

The new Gilibrator system is the only airflow calibrator with interchangeable flow cells. This unique Gilian design allows you to choose from three individual flow ranges.

  • High (2-30 LPM)
  • Standard (20cc-6 LPM)
  • Low (1-250 cc/min)

The Gilian Gilibrator electronics are programmed to calculate the air flow rate, average flow rate, and the test number of each sequence automatically. A manual Delete function will subtract erroneous readings from the average. The Gilibrator's control unit base features a large easy-to-read LCD display and select buttons for easy calculation of data. An auto-averaging button automatically averages the data during the calibration period. It states the number of calibrations and the average flow rate. The Delete button allows the erroneous bubble reading to be removed from the running average, and reset back to the previous reading. A reset button is a quick way to initialize a new calibration sequence and set the display back to zero.

Features:

  • Interchangeable flow cell mount
    Each cell is designed to twist onto the electronics base. This enables you to install each cell quickly, without screws or clips.
  • Automatic bubble generator
    At the base of the flow cell is the bubble generator. By pushing the button down, a ring lowers itself into the soap solution, creating a perfect film. Releasing the button lifts the film to the flow tube automatically.
  • Built-in infrared bubble sensors
    This feature senses when the bubble passes the lower sensor, then the upper sensor. The electronics then calculate the flow rate of the bubble and indicate the reading on the LCD display.
  • Interchangeable flow cells
    The new Gilibrator system is an easy-to-use primary flow calibrator. This unique system features three interchangeable flow cells that incorporate twist on/twist off mounting. This allows the user to buy one unit and simply switch the flow cell chamber for a specific calibration range.

    Flow cell ranges include a high flow of 2-30 LPM to calibrate large scale high volume samplers. A standard range will cover most of your flow equipment ranges from 20cc-6LPM. For ultra low flow calibration, Gilian offers a 1-250cc/min flow cell ideal for calibrating samplers with sorbent tubes in line.
  • Pulsation dampers
    The pulsation damper removes pulsation from the flow source for higher accuracy sampling as well as eliminating pulsations back into the flow source during bubble generation.
  • Average, delete, and reset functions
    Successive readings can be taken and the Gilibrator will automatically average the readings taken during that trial. If an error is made due to an improper bubble, that reading may be deleted from the average and brought back to the previous average. To reset the system, which initiates a new averaging sequence, simply press Reset.
  • Run and charge LEDs
    When the first infrared sensor is tripped, the RUN LED will light. This will prevent you from inadvertently initiating another bubble during the run. The charge LED indicates that the battery is being charged.
  • Rechargeable battery system
    This enables you to use the Gilibrator anywhere, in the lab or in the field. When fully charged, the Gilibrator will operate for a period of eight hours The unit can also be used on AC current.
Specifications
Flow cell operating ranges High flow cell: 2-30 LPM
Standard flow cell: 20cc-6 LPM
Low flow cell: 1-250 cc/min
Bubble generator Push-button bubble generator lifts an even soap film from the reservoir and provides consistent bubble film generation.
Pulsation damper Built-in automatic damper eliminates pulsations
Micro-processor control unit
Auto-averaging Provides an instantaneous average of multiple flow readings and is indicated on the display.
Flow delete Provides a means to delete an erroneous reading should an improper bubble be generated. This allows the user to maintain an accurate running average and reset back to the previous value.
Reset Provides the user with the ability to reset the unit back to zero to begin a new calibration sequence.
Programmable update The electronics design allows programmable updates to assure a long, useful service life.
Accuracy Over 99%

Please contact us for more information on the Gilian Gilibrator


Agilent
E4437B

Agilent E4437B
Yokogawa
WT1600B


Yokogawa WT1600B
Anritsu
MS2026A

Anritsu MS2026a
Megger
DLRO-200-115

Megger DLRO-200-115

Teseq
NSG437
Varian 956 Porta Test
Solar
7054-1

Chauvin Arnoux 6121
Chroma
63209
Chroma 63209
Privacy Notice Site Map Terms of Use
Copyright © 1996-2007  |  Advanced Test Equipment Rentals  |  All Rights Reserved