Advanced Test Equipment Corporation Rentals - Sales - Service
Advanced Test Equipment Corporation
1-888-404-ATEC (2832)
tagline

      The Knowledge. The Equipment. The Solution


spacer

Home - Hipot/UL/Electrical Testers
Rod-L M100DC
Rod-L M100DC DC Hi-Pot Tester
(M100 AC Hi-Pot Testers also available)

Production/Ouality Assurance Testing

  • Fully Automatic test cycle
  • Detects and indicates the following :
    • Test Ready (Security Chassis Ground Sensed)
    • Test in Progress
    • Test Passed
    • Test Failed
  • Following test parameters easily preset via rear panel potentiometers:
    • voltage ramp
    • test time
    • test voltage
  • Overcurrent trip point
  • Switch-selectable ramp & test time combinations
  • Arc detection circuit
  • Overcurrent detection circuit
  • Solid state HV generation and control system for reliability
  • Switchable "burn" feature permits destructive testing by maintaining output voltage, following failure, to the DUT throughout duration of preset test time
  • Can be interconnected with M25 Ground Continuity Test Instrument or any Rod-1. AC Hipot Test Instrument to simplify multiple testing requirements

Continuous Ground Continuity Monitoring

  • Monitors Ground Continuity of DUT before and during each Hipot Test
  • Senses for 0.5 (standard), at =1 .5 VAC
  • Loss of safety ground connection during a test causes high voltage to shut down with both audible and visual failure indication
  • Inhibits application of high voltage it the security chassis ground is not secure

Superior Safety Features

  • Front panel receptacle is rated to 8000 VAC
  • Front panel receptacle prevents direct operator exposure to high voltage during test
  • Shutdown within 2 milliseconds after dielectric break-down, overcurrent, or ground continuity fault
  • Electronically controlled output voltage ramp rate circuit guarantees consistently smooth ramp
  • Visual (audible optional) indication of high voltage applied to DUT
  • Discharge circuit provides for rapid discharge of DUT following shutdown
  • Visual and audible indication of the following :
    • arc detection
    • excessive overcurrent flow
    • ground continuity test failure

Please contact us for more information on the Rod-L M100DC


Haefely
ECOMPACT4

Haefely Ecompact 4
CA Instruments
5001ix


California Instruments 5001ix
Voltech
PM6000

Voltech PM6000
IFI
T4026-40

IFI T4026-40

Teseq
NSG437
Varian 956 Porta Test
Solar
2654-1

Solar 2654-1
Terms & Conditions Privacy Notice Site Map Terms of Use
 
Copyright © 1996-2008  |  Advanced Test Equipment Rentals  |  All Rights Reserved