Rent Schaffner / Teseq NSG3025 EFT/ Burst Generator for IEC 61000-4-4: EFT/Burst Immunity  Testing

Schaffner / Teseq NSG3025

 

Rent Haefely PEFT4010 EFT/Burst Generator for IEC 61000-4-4: EFT/Burst Immunity Testing

Haefely PEFT4010
EFT/Burst Generator


 

Rent NoiseKen INS-4020 Impulse Noise Simulator for IEC 61000-4-4: EFT/Burst Immunity  Testing

NoiseKen INS-4020
Impulse Noise Simulator

 

Rent EM Test UCS-500N5 Multi Tester for IEC 61000-4-4: EFT/Burst Testing

EM Test UCS-500N5 Multi Tester

 

Establishes a common and reproducible reference for evaluating the immunity of electrical and electronic equipment when subjected to electrical fast transient/bursts on supply, signal, control and earth ports. The test method documented in IEC 61000-4-4 describes a consistent method to assess the immunity of an equipment or system against a defined phenomenon.
 

The standard defines:

-test voltage waveform
-range of test levels
-test equipment
-verification procedures of test equipment
-test set-up
-test procedure


The standard gives specifications for laboratory and post-installation tests.
 


EFT Background

Electrical Fast Transients (EFT) are caused anytime a gaseous discharge occurs (a spark in air or other gas), the most common being the opening of a switch through which current is flowing. As the switch is opened, arcing occurs between the contacts; first at a low voltage and high frequency while contacts are close together, and later at a higher voltage and lower frequency as the contacts become separated. Coupling of the EFT into electronic products occurs when power cables handling high currents are run in close proximity to power, data, and/or I/O cables.
 

Electronic products are tested for EFT immunity to insure their continued reliable operation if subjected to realistic levels of fast transients. The European Union’s EMC Directive mandates EFT testing for virtually all electrical and electronic products as a condition for obtaining the CE Mark before shipping to a member state of the European Union.
 

Applicable Standards


Generic Immunity, Product and Product Family Standards require that EFT tests be performed in accordance with Basic EMC Standards: IEC 801-4, IEC 61000-4-4 or EN 61000-4-4. Thermo KeyTek’s Application Note, “EMC Standards Overview,” provides an overview of European Standards for electromagnetic compatibility, describes how the Standards relate to one another, and lists sources for procuring copyrighted documents.
1 IEC 801-4, IEC 61000-4-4, and EN 61000-4-4 are essentially the same for test voltages and levels.

 

Basic EMC Standard


The Basic EMC Standards for EFT define methods of generating consistently reproducible fast transients for test purposes. They specify generator and coupler/decoupler design and performance in an attempt to produce correlation results between test sites. The Basic EMC Standard specifies how to perform EFT testing, the Generic, Product and Product Family Standards specify the test levels and pass/fail performance criteria.
 

Test Levels


Standard Applicability Test Voltage
EN 50082-1 Generic Immunity - Residential, Commercial and Light Industrial 1kV
EN 50082-1
Draft
Draft Generic Immunity - Residential, Commercial and Light Industrial 1kV
EN 50082-2 Generic Immunity - Industrial Environment 2kV
EN 50082-2Draft Generic Immunity - Industrial Environment 2kV
EN 55104 Immunity for Household Appliances, Tools and Similar Apparatus 1kV

Test Set-Up






Coupling Methods


Capacitive Coupling via 33nF capacitors is the required coupling method to AC or DC power mains. These coupling capacitors are included as part of a Coupler/ Decoupler (C/D) in commercially available EFT simulators. The design of the decoupling portion of the C/D, which prevents the EFT burst from traveling back onto the power mains, is also specified in IEC 61000-4-4.

A Capacitive Coupling Clamp is used to couple EFT bursts onto data, I/O, and telecommunications lines. Construction of the clamp is shown in Figure 5 of IEC 61000-4-4; however, considerable differences exist in commercially available clamps. Some clamps use higher quality materials and some designs allow for the use of an optional safety interlocked cover.


Waveforms



Waveform Verification


IEC 61000-4-4 requires that the simulator output be verified periodically. A 50 ohm load and attenuator rated for high voltage is required and the measurement must be made using an oscilloscope with at least 400MHz bandwidth.


One problem noted with IEC 61000-4-4 is that simulator designs can be quite different and although each has a 50 ohm source impedance and provides the specified pulse into a 50 ohm termination, some simulators provide significantly more or less energy than others into loads that are not 50 ohms - the AC power input of most electronic products is something other than 50 ohms. To deal with the problems, changes to the standard were proposed to require waveforms be verified into a 1000 ohm load. Unfortunately, these changes were not accepted; however, this and other proposed improvements to IEC 61000-4-4 will be included in a forthcoming Annex.
 

Test Execution


According to IEC 61000-4-4, testing must be carried out according to the manufacturer’s test plan, which shall specify:

Type of Test Test Levels
Polarity (+ & - required) Test duration (1 minute minimum)
Number of Voltage tests EUT ports
EUT operating condition Sequence to tests to ports, etc.
Auxiliary equipment  

EUT Performance Criteria


For EFT tests, the Generic Immunity Standards and Household Appliances Product Family Standard require that products operate as intended after the test. No degradation or loss of function is allowed below a performance level specified by the manufacturer. During the test, degradation is allowed, but not a change in the actual operating status or data storage. Refer to the tables located in the Generic, Product and Product Family Standards for specific Performance Criteria. The product cannot become unsafe under any conditions.


EFT Simulators


EFT Simulators produced by Thermo KeyTek meet all the simulator requirements of |IEC 61000-4-4, including discharge pulse energy, output type, dynamic source impedance, and all waveform characteristics. Additionally, Thermo KeyTek simulators meet the requirements for coupling/decoupling networks for AC and DC mains as described in paragraph 6.2 of IEC 1000-4-4.

Information Retrieved from Thermo Scientific.