Haefely MAG 100 Power Frequency Magnetic FieldTest Equipment
To be used for EMC Tests requiring
AC Magnetic Fields
Power frequency magnetic fields are
generated by AC current flowing in conductors. The normal 50/60Hz mains
power cord is a good example, although currents with other frequencies may
be present dependant on the application. Magnetic fields, may interfere
with equipment operated in close proximity. Typical EUTs are monitors of
all kinds.
The Haefely MAG 100 has a 1m x 1m square,
single turn antenna. A current of 120A is needed to feed the coil to
produce a field of 100A/m. The Haefely MAG 100 includes a current
transformer capable of delivering 120A from a low current source.
Magnetic field strength is defined at the
center of a coil with ±3dB variation. Magnetic field is orthogonal to the
coil plane. Coil dimensions define the maximum EUT size as being 0.6m x
0.6m x 0.5m. The MAG100 can be used for both vertical and horizontal plane
testing, by simply rotating the coil antenna in its mounting on the
(optional) stand. The Haefely MAG-100 can only be used for continuous mode
testing.
In conjunction with other Haefely EMC Test
products, magnetic field testing can be fully or partially automated. The
Haefely PLINE 1610 used together with the MAG 100 can provide semi
automatic testing from the instrument front panel. A special menu MAG100
is included in the PLINE 1610 software. Voltages can be programmed which
correspond to a magnetic field strength at the center of the coil antenna.
Provides a solution for:
Features:
-
up to 110A/m field strength
-
different coil sizes available
-
exactly as defined in IEC 1000-4-8
-
sturdy construction
-
horizontal and vertical testing
possible
-
Supplied to ISO 9001
-
software control (when used together
with Haefely EMC power sources)
-
single turn coils
| Technical
Specifications |
| Input
Voltage range |
0
- 230V |
| Output
Voltage range |
0
- 1.2V |
| Output
Current range 1 |
0
- 13A |
| Output
Current range 2 |
0
- 130A |
| Maximum
EUT size |
0.6
x 0.6 x 0.5m |
| max
field 1m x 1m coil |
110
A/m |
| max
field 2m x 2.6m coil |
36
A/m |
| Input connection |
10A
IEC |
|