Rentals - Sales - Service Advanced Test Equipment Corporation 1-888-404-ATEC (2832) |
||
![]() The Knowledge. The Equipment. The Solution |
|
| Home - Network Tools | ||||||||
| Megger CFL535E | ||||||||
![]() |
Time Domain Reflectometer CFL535E - TDR2000
1km, 2km, 4km, 8km, 16km. Resolution: 0.1m up to 200m 0.2m up to 400m 0.1% of range above 400m Measurement Accuracy: 0.1% of Range [Note – The measurement accuracy is for the indicated cursor position only and is conditional on the velocity factor being correct.] Input Protection: The inputs will withstand 150Vdc or 150Vac up to 500Hz. Output pulse: 14 volts peak to peak into open circuit, 7 volts peak to peak into 120Ω Pulse width user selectable: 50m range: 20ns, 40ns, 60ns, 80ns, 100ns 100m range: 20ns, 50ns, 800ns, 100ns, 140ns 200m ranges: 20ns, 60ns, 100ns, 140ns, 200ns 400m range: 40ns, 80ns, 160ns, 200ns, 400ns 1km range: 80ns, 160ns, 260ns, 500ns, 1μs 2km range: 160ns, 260ns, 500ns, 1μs, 2μs 4km range: 250ns, 500ns, 1μs, 2μs, 4μs 8km range: 500ns, 1μs, 2μs, 4μs, 8μs 16km range: 1μs, 2μs, 4μs, 8μs, 16μs Gain: 0 to 90dB in steps of 6dB Velocity Factor: Variable from 0.300 to 0.999 in steps of 0.001 Repetition rate: Burst of 256 pulses every 1 or 10 seconds. Output impedance: Balanced 120Ω Balance Adjustment: 0Ω to 120Ω Update Rate: Once per second. Power Down: Automatic after 5, 10 or 15 minutes with no key press, user selectable. Backlight: Stays on for 1, 2 or 5 minutes when activated, user selectable. EMC:Complies with Electromagnetic Compatibility Specifications (Light industrial) BS/EN50081-1-1992 BS/EN50082-1-1992 |
|||||||
|
Please contact us for
more information on the Megger CFL535E
|
||||||||
|
|||||||
|
|||||||