35677A S-Parameter Test Set
- Frequency Range: 100 kHz to 200 MHz
- Test Port Impedance: 50 ohm
- Directivity: >40 dB
- Frequency Response
* Transmission (S21, S12): ±1 dB, ±5 degrees
* Reflection (S11, S22): ±1 dB, ±5 degrees
- Port Match
* Test Ports 1, 2: > 26 dB
* Test Ports 1, 2 Open/Short Ratio: < ±0.75 dB magnitude and < ±5 degrees
phase
* Input Port: > 20 dB return loss
* Output Ports A, B, and R: > 26 dB return loss
- Test Port Isolation: > 100 dB
- Insertion Loss
* RF Input to Test port 1 or 2: typically 13 dB
* RF Input to Output Ports A, B, or R: typically 19 DB
* RF Input Maximum Operating Level: +25 dBm or ±30 Vdc
- Connectors
* Input Port and Output Ports A, B, and R: 50 ohm type N female
* Test Ports 1 and 2: 50 ohm type N female
* DC Bias Inputs: BNC female, rear panel
* DC Bias Range: Typically ±30 Vdc and ±20mA with some degradation of RF
specifications; 200 mA damage level
- Accessories Supplied
* 4 ea. 50 ohm cables with Type N male connectors for connection to HP 3577A
* 1 ea. Test Set interconnect cable to HP 3577A
Or can be used with HP /
Agilent 35677B S-Parameter Test set.
- Test Port Impedance: 75 ohm
|
|
Audio/Video/Baseband/IF Network Analyzer, 5 Hz to 200 MHz
- High speed/high accuracy measurements
- 0.001 dB, .005 degree, 1 ps, .001 Hz resolution
- Built-in three-term error correction plus normalization
- Magnitude, phase, polar, real, imaginary, and group delay display modes
- Convenience features including direct plotter control and vector math functions
Source
- Frequency
* Range: 5 Hz to 200 MHz
* Resolution: 0.001 Hz
- Amplitude
* Range: +15 dBm to -49 dBm
* Resolution: 0.1 dB
- Impedance: 50 ohm
- RF Output Connector: 50 ohm type N female
- Sweep Types: Linear, alternate, cw and log frequency; log amplitude
- Sweep Time: 100 ms/span to 200 ms/span for frequency sweep; 1 ms/step to 16
s/step for amplitude sweep
- Sweep Modes: Continuous, single, manual
- Trigger Modes: Free run, immediate, line, external
Input Characteristics
- Frequency Range: 5 Hz to 200 MHz
- Inputs: Three receiver inputs (A, B and R)
- Input Impedance: Selectable 50 ohm or 1 Mohm in parallel with approximately 30 pF
- Input Connectors: 50 ohm Type N female
- Resolution Bandwidth: Selectable 1 kHz, 100 Hz, 10 Hz or 1 Hz
* Sensitivity (Due to noise and internal crosstalk between source and receiver
inputs) 1 Hz: -130 dBm
Magnitude Characteristics
- Range: Full scale input to sensitivity
- Resolution
* Marker: 0.001 dB (log); 5 digits (linear)
* Display: 0.01 dB/div to 20 dB/div (log absolute); 0.01 dB/div to 200 dB/div (log
ratio)
- Display Units: dB, dBm, dBV, V, and linear ratio
- Reference Level - Range: -207 dBm to +33 dBm
Phase Characteristics (A/R, B/R, A/B)
- Range: ±180 deg
- Resolution
* Marker: 0.005 deg (0.001 rad)
* Display: 0.01 deg/div to 200 deg/div (0.00018 rad/div to 3.49 rad/div)
Delay Characteristics
- Range: 1 ps to 20.000s
- Resolution: .01 ns/div to 1000 s/div
General Display Characteristics
- Traces
* Two simultaneous traces may be present with a rectangular graticule. One
trace with polar or Smith graticules
* Markers: Each trace has one main marker and an offset marker
- Graticules
* Rectangular Graticule: 0% to 100% full scale deflection in 0.05% increments.
Logarithmic and Linear
* Polar/Smith Chart Graticule: ±500 deg in 0.001 deg increments
- Noise Averaging
- Linear Phase Slope Compensation
- Calibration: Transmission; Reflection
Programming Characteristics
Capability: Remote programming via the Hewlett-Packard interface bus
(HP-IB)
General Characteristics
- External Reference Frequency Input
* Frequency: 10 MHz/N. N is an integer from 1 to 100
- Reference Frequency Output
* Frequency: 10 MHz
* External Trigger
* Plotter Control: Directly compatible with HP-IB graphics plotters
* Save/Recall
|