HP / Agilent 3577A with 35677A Audio/Video/Baseband/IF Network Analyzer, 5 Hz to 200 MHz

35677A S-Parameter Test Set

  • Frequency Range: 100 kHz to 200 MHz
  • Test Port Impedance: 50 ohm
  • Directivity: >40 dB
  • Frequency Response
    * Transmission (S21, S12): ±1 dB, ±5 degrees
    * Reflection (S11, S22): ±1 dB, ±5 degrees
  • Port Match
    * Test Ports 1, 2: > 26 dB
    * Test Ports 1, 2 Open/Short Ratio: < ±0.75 dB magnitude and < ±5 degrees phase
    * Input Port: > 20 dB return loss
    * Output Ports A, B, and R: > 26 dB return loss
  • Test Port Isolation: > 100 dB
  • Insertion Loss
    * RF Input to Test port 1 or 2: typically 13 dB
    * RF Input to Output Ports A, B, or R: typically 19 DB
    * RF Input Maximum Operating Level: +25 dBm or ±30 Vdc
  • Connectors
    * Input Port and Output Ports A, B, and R: 50 ohm type N female
    * Test Ports 1 and 2: 50 ohm type N female
    * DC Bias Inputs: BNC female, rear panel
    * DC Bias Range: Typically ±30 Vdc and ±20mA with some degradation of RF specifications; 200 mA damage level
  • Accessories Supplied
    * 4 ea. 50 ohm cables with Type N male connectors for connection to HP 3577A
    * 1 ea. Test Set interconnect cable to HP 3577A

Or can be used with HP / Agilent 35677B S-Parameter Test set.

  • Test Port Impedance: 75 ohm

Audio/Video/Baseband/IF Network Analyzer, 5 Hz to 200 MHz

  • High speed/high accuracy measurements
  • 0.001 dB, .005 degree, 1 ps, .001 Hz resolution
  • Built-in three-term error correction plus normalization
  • Magnitude, phase, polar, real, imaginary, and group delay display modes
  • Convenience features including direct plotter control and vector math functions

Source

  • Frequency
    * Range: 5 Hz to 200 MHz
    * Resolution: 0.001 Hz
  • Amplitude
    * Range: +15 dBm to -49 dBm
    * Resolution: 0.1 dB
  • Impedance: 50 ohm
  • RF Output Connector: 50 ohm type N female
  • Sweep Types: Linear, alternate, cw and log frequency; log amplitude
  • Sweep Time: 100 ms/span to 200 ms/span for frequency sweep; 1 ms/step to 16 s/step for amplitude sweep
  • Sweep Modes: Continuous, single, manual
  • Trigger Modes: Free run, immediate, line, external

Input Characteristics

  • Frequency Range: 5 Hz to 200 MHz
  • Inputs: Three receiver inputs (A, B and R)
  • Input Impedance: Selectable 50 ohm or 1 Mohm in parallel with approximately 30 pF
  • Input Connectors: 50 ohm Type N female
  • Resolution Bandwidth: Selectable 1 kHz, 100 Hz, 10 Hz or 1 Hz
    * Sensitivity (Due to noise and internal crosstalk between source and receiver inputs) 1 Hz: -130 dBm

Magnitude Characteristics

  • Range: Full scale input to sensitivity
  • Resolution
    * Marker: 0.001 dB (log); 5 digits (linear)
    * Display: 0.01 dB/div to 20 dB/div (log absolute); 0.01 dB/div to 200 dB/div (log ratio)
  • Display Units: dB, dBm, dBV, V, and linear ratio
  • Reference Level - Range: -207 dBm to +33 dBm

Phase Characteristics (A/R, B/R, A/B)

  • Range: ±180 deg
  • Resolution
    * Marker: 0.005 deg  (0.001 rad)
    * Display: 0.01 deg/div to 200 deg/div (0.00018 rad/div to 3.49 rad/div)

Delay Characteristics

  • Range: 1 ps to 20.000s
  • Resolution: .01 ns/div to 1000 s/div

General Display Characteristics

  • Traces
    * Two simultaneous traces may be present with a rectangular graticule.   One trace with polar or Smith graticules
    * Markers: Each trace has one main marker and an offset marker
  • Graticules
    * Rectangular Graticule: 0% to 100% full scale deflection in 0.05% increments.   Logarithmic and Linear
    * Polar/Smith Chart Graticule: ±500 deg in 0.001 deg increments
  • Noise Averaging
  • Linear Phase Slope Compensation
  • Calibration: Transmission; Reflection

Programming Characteristics
Capability: Remote programming via the Hewlett-Packard interface bus (HP-IB)

General Characteristics

  • External Reference Frequency Input
    * Frequency: 10 MHz/N.  N is an integer from 1 to 100
  • Reference Frequency Output
    * Frequency: 10 MHz
    * External Trigger
    * Plotter Control: Directly compatible with HP-IB graphics plotters
    * Save/Recall


Please contact us for more information on the HP / Agilent 3577A with 35677A Audio/Video/Baseband/IF Network Analyzer, 5 Hz to 200 MHz

Similar Test Equipment

Rent Anritsu MS2024A Vector Network Analyzer
Anritsu MS2024A
Vector Network Analyzer

Rent Agilent E5071C Network Analyzer
Agilent E5071C
Network Analyzer

Rent Agilent E8802A PNA Network Analyzer
Agilent E8802A
PNA Network Analyzer

Rent Agilent N5230A PNA-L Network Analyzer
Agilent N5230A
PNA-L Network Analyzer

Rent Agilent N9310A RF Signal Generator
Agilent N9310A
RF Signal Generator

Forms Terms & Conditions Privacy Notice Home Page Terms of Use
Copyright © 1996-2010  |  Advanced Test Equipment Rentals  |  All Rights Reserved