Rentals - Sales - Service
Advanced Test Equipment Rentals
Toll Free: 1-800-404-ATEC (2832)
Follow ATEC on LinkedInFollow ATEC on YouTubeFollow ATEC on TwitterFollow ATEC on Facebook



Home - Meters - RF Power
Home > Manufacturer > Agilent

HP/ Agilent 478A Coaxial Thermistor Mount

The H75 and H76 are options for the 478A that represent optimized performance for VSWR


Agilent 478A Coaxial Thermistor Mount

The Hp 478A Coaxial Thermistor Mount is designed for use with the HP Model 431 and 432 Power Meters to measure microwave power from 1 μW to 10 mW. Design of the mount minimizes adverse effects from enviromental temperature changes during measurement. For Increased measurement accuracy, Effective Efficiency and Calibration Factor are measured for each mount, and at selected frequencies across the operating range; the results are marked on the label of the instrument.

Features:

  • High accuracy even in routine power measurements
  • Temperature compensated for low drift
  • Measures microwave power as low as one microwatt
  • Shows calibration factor and effective efficiency at 12 frequencies
  • Frequency Range: 10 MHz to 10 GHz
  • Maximum SWR: 10 MHz to 25 MHz 1.75; 25 MHz to 7GHz 1.30; 7 GHz to 10 GHz 1.50
  • Available options: 478A-H75 and 478A-H76 for frequency range 1 MHz to 1 GHz (Max. SWR 1.3, 1.05 at 50 MHz). 478A-H76 provides standard lab calibration at 50 MHz

Specifications:

Frequency Range 10 MHz to 10 GHz
Mount Calibration Calibration Factor and Effective Efficiency furnished at six frequencies
between 10 Mhz and 10 GHz
Impedance 50 ohms
Maximum Reflection Coefficient 10 to 25 MHz 0.273 (1.75 SWR, 11.3 dB return loss)
25 MHz to 7 GHz 0.13 (1.3 SWR, 17.7 dB return loss)
7 to 10 GHz 0.2 (1.5 SWR, 14 dB return loss)
Operating Resistance 200 ohms
Power Range 1 μW to 10 mW
Maximum Peak Power 200W
Maximum Average Power 30 mW
Maximum Energy per Puls 10W • μs for a PRF ≥1HHz
5 W • μs for a PRF kHz
Elements Field-replaceable, thermally balanced thermistor assembly
Thermistor assembly field adjustable so that full "zero-set" capability can be restored in the event inadvertent overload (mount calibration no longer valid)
RF Connector Type -N male, compatible with female connectors whose dimensions conform to MIL-C- 71 or MIL-C-39012. Brass connector.
Output Connector Mates with 431 and 432 cables.
weight net, 5 0z (140 g)
Shipping, 1lb (450 g)

Please contact us for more information on the 478A Coaxial Thermistor Mount

Featured Test Equipment:

Rent an Haefely ECompact 4 Transient Immunity Test Set

Haefely ECOMPACT4
Transient Immunity Test

Voltech PM6000
Voltech PM6000
Power Analyzer



IFI T4026-40
TWT Amplifier

Varian 956 Porta Test
Teseq NSG 438
ESD Gun

Solar 2654-1
Solar 2654
Transient Generator

Forms Terms & Conditions Privacy Notice Home Page Terms of Use