HP / Agilent 83492A Clock Recovery Module
The Agilent 83492A is designed to operate in an Agilent
83480A and an Agilent
86100A digital communications analyzer. These modules recover clock and data information at standard
telecom and datacom rates. The resulting trigger
signal is made available to the Agilent 83480A mainframe via a connector located
on the modules rear-panel. An external front-panel cable passes the
data signal, with some insertion loss, to the receiver module.
| Wavelength range (characteristic) |
750 nm to 860 nm and |
|
1000 nm to 1600 nm |
| Optical INPUT and OUTPUT fiber
(characteristic) |
62.5/125 multimode |
| Optical insertion loss (through
path) |
|
| 750 nm to 860 nm |
≤ 5.0 dB |
| 1000 nm to 1600 nm |
≤ 5.0 dB |
| Optical return loss |
≥ 28 dB |
| Clock Recovery Phase
Locked Loop Bandwidth (characteristic) |
| Internal Path Triggering |
50 to 70 kHz |
| External Output |
4 to 5 MHz |
| Clock recovery rates (NRZ coding) |
|
| 155.52 Mb/s |
±0.1% |
| 622.08 Mb/s |
±0.1% |
| 1062.50 Mb/s |
±0.1% |
| 1250 Mb/s |
±0.1% |
| 2125.00 Mb/s |
±0.1% |
| 2488.32 Mb/s |
±0.1% |
| 2500.00 Mb/s |
±0.1% |
| Data triggering (characteristic) |
50 Mb/s to 2500 Mb/s |
| Operating input power
level |
| 750 nm to 860 nm |
|
| Triggering
operation,all rates |
10 dBm to 3 dBm |
| 10 10 BER, all rates |
10 dBm to 3 dBm |
| 1000 nm to 1600 nm |
|
| Triggering
operation,all rates |
13 dBm to 3 dBm |
| 10 10 BER,
all rates |
13 dBm to 3 dBm |
| Output jitter, all rates |
0.0125 UI rms |
Maximum continuous optical
power
before damage (characteristic) |
10 mW peak |
DATA and CLOCK output amplitude,
all rates (characteristic) |
0.5Vp-p |
|