100kHz-4.2GHz Peak Power Sensor
The HP / Agilent 84813A 100kHz-4.2GHz Peak Power Sensor is compatible with the obsolete 8990/1A peak power analyzers and the obsolete 8992A digital video power analyzer. This sensor gives you outstanding measurement accuracy in demanding situations and includes automatic temperature sensing and correction.
Specifications
| Frequency Range |
500 MHz to 26.5 GHz |
| Dynamic Range |
-32 to +20 dBm (Usable to -40 dBm.) |
| Sensor Calibration |
< 4 GHz: ±3.6% |
| RSS Uncertainty |
| < 12 GHz: ±3.8% |
| < 18 GHz: ±4.3% |
| < 26.5 GHz: ±5.5% |
| < 40 GHz: ±6.5% |
| Input SWR, max |
500 MHz to 18 GHz: 1.25 (0.11) |
| Reflection Coefficient |
| 18 to 26.5 GHz: 1.35 (0.15) |
| 26.5 GHz to 40 GHz: 1.60 (0.23) |
| Maximum Power Input |
1 W peak power for 1 µs, not to exceed 200 mW (CW) |
| Operating Temperature |
0°C to +55°C |
| Connector |
APC-3.5 mm Male |
| Sensor Cable Length |
1.5 M (5 ft) |
| Option 001 |
6.1 M (20 ft) |
| Dimensions |
27mm H, 37mm W, 127mm L (1.05" x 1.45" x 5.0") |
| Weight |
Net: 0.35 kg (0.8 lb); Shipping: 1 kg (2 lb) |
| Option 001 |
Net: 0.8 kg (1.5 lb); Shipping: 1.5 kg (3 lb) |
|