Option H26: 4 to 2600MHz (50 ohms)
|
|
Agilent 8502A Transmission/ Reflection Test Set 500 kHz-1.3 GHz
The HP 8502A Transmission set provides all of the RF hardware necessary to make simultaneous
transmission and reflection measurements between 500 kHZ and 1300 MHz. The test set consists of
an RF power splitter to develop a reference or incident signal, a directional bridge to develop a reflected signal,
and a attenuator to control the signal incident on the device under test.
Specifications:
| Frequency Range |
500 kHz to 1.3 GHz |
| Impedance |
50 ohms |
| Directivity |
> 40 dB |
| Transmission |
| Magnitude |
>± 0.8 dB |
| Phase |
< ± 8° |
|