HP / Agilent 8970B Noise Figure Measurement: |
- Measurement range: 0 to 30 dB
- Instrumentation Uncertainty: ±0.1 dB
- Resolution: 0 .01 dB (0.001 dB over GPIB)
|
HP / Agilent 8970B Input Specifications: |
- Frequency Range: Tunable from 10 to 1600 MHz (10 to 2047 MHz
with option 020)
- Tuning Accuracy (for 10 to 40°C): ±(1
MHz + 1% of frequency); 6 MHz maximum
- Frequency Resolution: 1 MHz
- Noise Figure (for input power levels below -60 dBm):
<7 dB + 0.003 dB/MHz (<7 dB +0.002 dB/MHz with option 020)
- Input SWR, 50 ohm reference impedance:
- <1.7 10 MHz to 1600 MHz; (<1.8 with option
020)
- <2.0 1600 MHz to 2047 MHz - (option 020 only)
- Maximum Operating Input Power: -10 dBm
- Maximum Net External Gain: >65 dB between noise
source and HP 8970B RF input
|
HP / Agilent 8970B General: |
- Noise Source Drive: 28.0 ±0.1
V for noise source On (up to 60 mA peak); <IV for noise source Off
- GPIB Capability: SH1, AH1, T5, TE0, L4, LE0, SR1, RL1, PP0,
DC1, DT, C0, E1
- Connectors: RF input: N(f), noise source drive: BNC (f)
- Power: 100, 120, 220 , or 240 V, 48-66
Hz, 150 VA max.
- Weight: 40 lbs (18.5 kg)
|
HP / Agilent 8970B Options: |
- Option 020 - Extends upper frequency from 1600 to 2047 MHz
- Option 700: External MATE translator
- Call for more options
|
|
|
HP / Agilent 8970B 10MHz-1.6GHz Noise Figure Meter
HP / Agilent 8970B Features: |
- Tunes its input frequency between 10 and 1600 MHz
- Controls an external LO for receiver or microwave measurements
- Controls the noise source to turn it On or Off
- Makes the noise power measurements
- Calculates the noise figure
- Removes the effects of the measurement system's noise
- Compensates for losses before or after the DUT
- Displays the results in either noise figure, effective noise
temperature (Ta), or Y factor
- Be assured of repeatable, accurate, and maintainable
microwave noise figure measurements
with the
HP / Agilent 8971C Noise Figure Test Set.
|
HP / Agilent 8970B Gain Measurement Range: |
- Measurement range: -20 to >+40 dB
- Instrumentation Uncertainty: ±0.15 dB
- Resolution:
- Gain >-9.99 dB: 0.01 dB
- Gain <-9.99 dB: 0.1 dB
|
HP / Agilent 8970B Supplemental Characteristics: |
- Bandwidth: Approximately 4 MHz
- Sensitivity: -100
dBm
- Measurement Speed: 6 to 9 measurements per second with
minimum smoothing
- Sweep Speed at Minimum Smoothing: Peak-to-peak Y-factor
variation <0.02 dB (for smoothing factor of 64)(typical)
- Maximum Safe Input Level: ±20 V dc; +20 dBm peak (or
average) at RF
- Audible Noise Level: <5.5 bels at 1 meter
|
HP / Agilent 8970B Functional Properties: |
- Noise Figure Display Units:
- Noise Figure: dB, ration
- Uncorrected Y factor: dB, ration
- Effective Input Noise Temperature: K
- Displayed Measurement Frequency Range: 10 to 99,999 MHz
- Hot Noise Source Data Range: ENR from -7 to +50 dB; spot Thot from 0 to >2.9x107 K
- Number of Calibration Points in One Sweep: 181
- Storage Capacity of Hot Noise Source Tables: 4 stored
ENR tables with 35 frequency's each (plus 1 working ENR table)
- Rear Channel Outputs: X axis and Y axis from 0 to 6V. Z
axis is TTL for penlift (on an X-Y plotter) blanking (on an
oscilloscope)
- Plotter Capability: Noise figure and gain versus
frequency plot with grid, title and noise figure, gain, and frequency
axis annotation
- Compatible Digital Plotters: HP 7470C, HP
7475A, HP 7550A, HP
7440A, HP 9872B
|
HP / Agilent 8970B Electromagnetic Compatibility: |
EMI: Conducted
and radiated interference is in compliance with MIL-STD-461B CE03, RE02, EN55011, CLASS A (1991) AND
CISPR, Class A
(1990).
Conducted and radiated susceptibility: meets
the requirements of MIL-STD-461B-1980, CS01/CS02, RS03 and EN50082-1 (1991)
(IEC
801-2, 801-3 and 801-4). |
|