Elgar SW10500-1-3-2 10.5kVA Smartwave System 1/3 PhaseThis system is comprised of one master chassis, one or more slave chassis, a power distribution (PDU) chassis, and an optional input power line filter (required for CE mark).
|
|||||||||||||||||||||||||||||
| Power Factor of Load | 0 lagging to 0 leading |
| AC or DC Output Voltage | to 156 VRMS L-N, range 1; 0 to 312 VRMS L-N, range 2 |
AC or DC Output Current Per Phase: |
13A to 135V in 156V range; 6.5A to 270V in 312V range (per 1750 VA module) Note: Higher currents may be achieved in 10.5-21 kVA systems. |
| Crest Factor: | 4.0 (peak output current to RMS output current) |
| Output Frequency Range | DC or 40 Hz to 5 kHz. For output frequencies greater than 1 kHz, the max slew rate allowed is 1 kHz per second. |
| Output Power: | 1750 VA: 1, 3500 VA: 1 or 2, 5250 VA: 1 or 3 (systems up to 21,000 VA) |
| Load Regulation: | 0.025% of full scale voltage for a full resistive load to no load; above 1 kHz, add 0.01%/kHz |
| Line Regulation | (DC, or 40 Hz to 5 kHz): 0.025% of full scale for a 10% input line change |
Voltage Accuracy |
0.1% of range. Above 1 kHz, add 0.2%/kHz. Add 0.1% of full scale for "AC PLUS DC" mode. Valid for 5 to 156 VRMS and 10 to 312 VRMS at 25C |
| Voltage Resolution | 0.05% of full scale |
| Frequency Resolution | 0.01 Hz: 40 Hz to 99.99 Hz 0.05 Hz: 100 Hz to 999.9 Hz 0.5 Hz: 1000 Hz to 5000 Hz |
Frequency Accuracy |
0.01% at 25C 0.001%/C Phase Accuracy, Phase-to-Phase Balanced Linear Resistive Load: 1, 40 Hz to 1 kHz, plus 1/kHz above 1 kHz |
| Balanced Linear Resistive Load | 1, 40 Hz to 1 kHz, plus 1/kHz above 1 kHz |
| Phase Angle Resolution | 0.1 |