Elgar
CW801P 800VA AC Power Source
The Elgar CW801P 800VA AC power source provides clean single phase power at an impressive price/performance ratio. This compact switch mode source is programmable with standard IEEE-488.2 or RS-232 control. It can be operated in a benchtop or rackmount configuration.
Power Factor Corrected (PFC) universal input voltage allows maximum power to be delivered from an AC outlet without the user selecting the range. Fully rated current is delivered for either output voltage range of 135 VAC or 270 VAC over a standard frequency range of 45 to 500
Hz. The Elgar CW801P can be paralleled to provide extra power. A separate output-on switch controls power to the load. Remote voltage sense is standard. Transformer coupled output is protected against overvoltage and overcurrent. The unit is also protected against
over temperature conditions. A two-speed fan results in quieter operation at lower power levels.
Elgar CW801P Output Specifications:
| Power |
| Power |
800 VA |
| Power factor of load |
0 lag to 0 lead |
| Phase |
Single Phase |
| Voltage |
| Range |
0 to 135 VRMS or 0 to 270 VRMS, user selectable |
| Accuracy |
±0.1% of range <100 Hz, ±0.2% of range,
>100 Hz (>5 VAC out) |
| Resolution |
0.1 VRMS |
| Total Harmonic Distortion |
0.25% typical <100 Hz add 0.5%/100 Hz above 100 Hz |
| AC Noise Level |
<50 mVRMS |
| Amplitude Stability |
±0.05% of full scale over 8 hours at constant line, load and temperature after 15 minute warm-up typical |
| Load regulation |
±0.1% of full scale voltage for a full resistive load to no load
(<10 mVRMS typical, measured at point of sense) |
| Line regulation |
±0.1% of full scale voltage for a ±10% line change from nominal line voltage
(<5 mVRMS typical, measured at point of sense) |
| Remote voltage sense |
Compensation for up to 5 VRMS total lead voltage drop |
| Current |
| Current |
0.0 - 6.0 A max per phase |
| Accuracy |
±0.6% max |
| Resolution |
0.01 ARMS |
| Frequency |
| Range |
45 to 1000 Hz optional |
| Accuracy |
±0.02% max |
| Resolution |
0.1 Hz, 0.01 Hz for remote programming |
| Phase Angle |
| Range |
-359 to +359 degrees. Positive phase indicates time lag from reference |
| Accuracy |
within 100 microseconds of equivalent angle |
| Resolution |
1 degree |
Elgar CW801P Measurement Specifications:
| Voltage |
| Range |
0 to 270 VRMS |
| Accuracy |
±0.1% of range <100 Hz, ±0.2% of range >100 Hz, measured at point of sense (>5 VAC out) |
| Resolution |
0.1 VRMS |
| Current |
| Range |
0 to 6.0 ARMS |
| Accuracy |
±0.6% of range for linear loads with current 0.2A for 800 VA & 1200 VA, 0.4A for 2500 VA |
| Resolution |
0.01 ARMS |
| Peak Current |
| Range |
0 to 25A |
| Accuracy |
±2% of range |
| Resolution |
0.1A |
| Frequency |
| Range |
45 to 500 Hz (45 to 1000 Hz optional) |
| Accuracy |
±0.02% of value |
| Resolution of display |
0.1 Hz |
| Power |
| Range |
0 to 800W |
| Accuracy |
±2% of range for linear loads |
| Resolution |
1W |
| Apparent Power |
| Range |
0 to 800 VA |
| Accuracy |
±2% of range for linear loads |
| Resolution |
1 VA |
| Power Factor |
| Range |
0 to 1 |
| Accuracy |
±4% of range for linear loads |
| Resolution |
0.01 |
| Crest Factor |
| Range |
0 to 3.5 |
| Accuracy |
±5% of range |
| Resolution |
0.01 |
Elgar CW801P Input Specifications:
| Voltage and Frequency |
| Voltage and Frequency |
90 to 264 VAC, 47 to 63 Hz, single phase |
| Current |
| Current |
13.5 A max per phase |
| Power Factor |
>0.99 typical at full load nominal line |
| Efficiency |
>73% typical at full load |
|