Power/Harmonic Scope Meter
Features
- Displays voltage, current and power waveforms
- Measures RMS, Peak and Total Harmonic Distortion of voltage and current
- Displays harmonic detail in bar graph format
- Measures harmonic power and indicates direction of flow
- Records Min/Max/Avg readings of voltage, current, power and frequency
Specifications
- True-rms voltage from 5.0V to 600V
- True-rms current from 1A to 500A (1000A with optional probe)
- Peak, DC, and Crest Factor
- Total harmonic distortion (%THDF and %THDR)
- Active power from 10W to 300kW (600kW with optional probe)
- Apparent power (kVA)
- Total power factor (PF)
- Displacement power factor (DPF)
- K-factor
- Frequency from 6Hz-99.9Hz (fundamental)
- Harmonics to 31st
- Phase angle of fundamental and harmonics
- Waveform and spectrum displays
- Record mode - MIN, MAX and AVG
- Zoom mode
- Handheld, 1 kg (2 lb)
- Includes 500A current clamp and video
|