| CONTROL CENTER |
| E103 |
ECAT Control Center with VFP, and FiberComTM Fiber-Optic interface & control; and Windows application software |
| Each control center includes one B-ECAT docking bay. Windows application software requires user-supplied IBM compatible computer, 486 or higher, 8MB RAM, one unused serial port, Windows 3.1 or higher |
| CONTROL CENTER OPTION |
| E103-S |
Oscilloscope trigger for installed surge modules |
| True-EFT SIMULATOR MODULES |
| IEC 61000-4-4 Edition 2 kV to 4.4 kV |
E411 |
to 4.4 kV (see E455X for compatible coupler/decoupler) |
| IEC 61000-4-4 Edition 2 kV to 4.4 kV |
E412 |
to 4.4 kV, built-in single-phase coupler/decoupler, 250 VRMS, 16A |
| IEC 61000-4-4 Edition 2 kV to 8 kV |
E421 |
to 8 kV (see E455X for compatible coupler/decoupler) |
| IEC 61000-4-4 Edition 2 to 8 kV |
E422 |
to 8 kV, built-in single phase coupler/decoupler, 250 VRMS, 16A |
| True-EFT OPTIONS |
| E4XX-2MHz |
Increases EFT burst frequency to 2 MHz at </= 3 kV,(available for single phase modules only; E411, E412, E421,E422) |
| E4XX-CH |
Adds Chirp to EFT modules |
| IEC 61000-4-4 |
CCL |
Capacitive Coupling Clamp |
| CCLC |
Clamp Cover |
| SURGE SIMULATOR MODULES |
| IEC 61000-4-5 ANSI/IEEE C62.41 Cat. B and UL 1449(8/98) at 3 kA |
E501B |
1.2/50us, 8/20us Combination Wave to 6 kV, 3 kA (compatible with CM-I/OCD and CM-TELCD coupler/decouplers) |
| IEC 61000-4-5 FCC Part 68 and ITU Rec K.17,K.20, and K.21 (formerly CCITT) |
E502B |
10/700µs and 0.5/700µs Telecom Waves (compatible withCM-TELCD Telecom coupler/decoupler) |
| IEC 61000-4-5 FCC CCITT |
E502K |
Telecom Waves for CCITT Rec K22: 10/700us and 1.2/50 µs (compatible with CM-TELCD Telecom coupler/decoupler). Note: the 1.2/50 µs waveform is NOT the same as the combination wave produced by the E501B |
| ANSI C62.41 Cat. A and B, and various UL Stds including UL 864 |
E503 |
Ring Wave to 6 kV: 0.5us/100 kHz at 200A and 500A max |
| UL 1449 |
E504A |
UL 1449 Combination Waves to 6 kV: 1.2/50 µs, 8/20 µs ; selectable short-circuit currents of 125A, 500A or 750A |
| FCC Part 68 |
E505A |
FCC Part 68 waveforms: <10/ >160 µs to 1650V, 200A; <10/ >560 µs to 880V, 100A; <2/ >10us to 2.5 kV, 1 kA |
| Telcordia GR-1089 CORE |
E506-4W |
4-wire Bellcore waveforms: <2/ >10 µs to 800V or 1500V at 100A, 2500V or 5000V at 500A; 2, 3, or 5-terminal (4-wire) telecom port surges |
| Telcordia GR-1089 CORE |
E508 |
Bellcore waveforms: 10/360us to 1kV at 100A; 2 or 3-terminal telecom port surges |
| Telcordia GR-1089 CORE |
E508-12P |
12-pair 10/360 µs Bellcore waveforms to 1 kV at 25A; for simultaneously testing to 12 pair telecom lines, require an E508 |
| ANSI/IEEE C62.41 Cat. B IEC 61000 4-5 to 10 kV and 5 kV |
E510A |
10 kV Combination Wave: 1.2/50 µs, 8/20 µs to 10 kV at 5 kA (If used with a Coupler/Decoupler, a model E455XkV C/D is required. (If purchased as an upgrade to an existing system, factory calibration is required.) |
| British. Telecom |
E511 |
Modified combination wave: 1.2/50 µs, 8/20us Combination Wave to 6 kV at 5 kA |
| UL 864 |
E513 |
Linear voltage ramps at 100V/µs to 2.5 kV; 500V/µs, 1 kV/µs, 5 kV/µs, and 10 kV/µs to 3 kV |
| E514 |
10/1000 µs current waveforms at 15A and 100A, 1.5 kV/µs ramps at 60A and 250A |
| Telcordia GR-1089 CORE |
E515 |
Bellcore: 10/250 µs 4 kV peak open-circuit voltage; 2 kA peak short-circuit current (Maximum configuration has three bays and E515 becomes the system base) |
| Telcordia GR-1089 CORE - New |
E518 |
E518 Telecordia GR-1089-CORE waveforms: 10/1000 µs 600V, 1kV at 100A/side; 10/1000 µs 2 kV for Protection Coordination Testing |
| IEC 61000-4-5 ANSI UL |
E521 |
Combination Wave to 20 kV, 10 kA with built-in 1-phase CDN: 277/480 VRMS, 32 A coupler/decoupler (Maximum configuration has three bays and E521 becomes the system base) |
| IEC 61000-4-5 ANSI UL |
E522 |
Combination Wave to 20 kV, 10 kA with built-in 3-phase CDN: 277/480 VRMS, 32A coupler/decoupler (Maximum configuration has three bays and E522 becomes the system base) |
| DC OPTION FOR E521 AND E522 |
| E521-DC |
Allows use of Surge Coupler/Decoupler on DC Powered Mains |
| E522-DC |
Allows use of Surge Coupler/Decoupler on DC Powered Mains |
| VOLTAGE AND CURRENT MONITORING OPTIONS FOR SURGE MODULES |
| E501B-VI |
Adds Voltage and Current monitoring to the E501B |
| E502B-VI |
Adds Voltage and Current monitoring to the E502B |
| E502K-VI |
Adds Voltage and Current monitoring to the E502K |
| E503-VI |
Adds Voltage and Current monitoring to the E503 |
| E504A-VI |
Adds Voltage and Current monitoring to the E504A |
| E505A-VI |
Adds Voltage and Current monitoring to the E505A |
| E506-VI |
Adds Voltage and Current monitoring to the E506 |
| E506-4W-VI |
Adds Voltage and Current monitoring to the E506 |
| E508-VI |
Adds Voltage and Current monitoring to the E508 |
| E510A-VI |
Adds Voltage and Current monitoring to the E510A |
| E511-VI |
Adds Voltage and Current monitoring to the E511 |
| E513-VI |
Adds Voltage and Current monitoring to the E513 |
| E514-VI |
Adds Voltage and Current monitoring to the E514 |
| E515-VI |
Adds Voltage and Current monitoring to the E515 |
| E518-VI |
Adds Voltage and Current monitoring to the E518 |
| E521-VI |
Adds 3-wire VI monitoring plus automatic software selection to the E521 |
| E522-VI |
Adds 5-wire VI monitoring plus automatic software selection to the E522 |
| ADDITIONAL SURGE MODULE OPTION |
| IEC 61000-4-5 FCC CCITT |
E502B-UPG |
Upgrade of E502 or E502A to E502B |
| SURGE COUPLER/DECOUPLERS FOR DATA LINES |
| IEC 61000-4-5 |
CM-I/OCD |
External 8-line Coupler/Decoupler for I/O Signal lines with Aux clamping protection: requires E501 series module |
| IEC 61000-4-5 |
CM-I/OCD-HS |
High Speed option for testing data rates to >100kHz: requires CM-I/OCD |
| IEC 61000-4-5 |
CM-TELCD |
External 2 or 4 line Coupler/Decoupler for Telecom lines to > 100 kHz; with Aux clamping protection: requires E501 or E502 series module |
| SURGE COUPLER/DECOUPLER FOR AC LINES |
| E551 |
Single-phase, 250 VRMS, 15/16A (normally shipped with 125V NEMA 5015 EUT Mains Connector, unless |
| DC OPTION FOR SURGE COUPLER/DECOUPLER |
| E551-DC |
Allows the use of Surge Coupler/Decouplers on DC power mains |
| VOLTAGE AND CURRENT MONITORING OPTIONS FOR SURGE COUPLER/DECOUPLER |
| E551-VI |
Adds automatic 3 wire selection for VI monitoring of surge to the EUT |
| SURGE ACCESSORIES |
| PK1001D |
6 kV Differential Surge Probe (10 ns risetime) |
| PK1002D |
10 kV Differential Surge Probe (15 ns risetime) |
| COMBINED SURGE/EFT COUPLER/DECOUPLERS |
| E4551A |
Single-phase, 250V RMS, 15/16A for up to 7 kV Surge and 8 kV EFT waves (normally shipped with 125V NEMA 5-15 EUT Mains Connector, unless otherwise specified) |
| E4552A |
Single-phase, 277 VRMS, 32A for up to 7 kV Surge and 8 kV EFT waves |
| E4553A |
Three-phase, 480 VRMS, 16A for up to 7 kV Surge and 8 kV EFT waves |
| E4554A |
Three-phase, 480 VRMS, 32A for up to 7 kV Surge and 8 kV EFT waves |
| E4556 |
Three-phase, 600 VRMS, 100A (for surge operation up to 10kV) Includes 5 wire VI monitoring capabilities (Maximum configuration has four bays and E4556 becomes the system base) |
| 10 kV COMBINED SURGE/EFT COUPLER/DECOUPLERS |
| E4551kV |
Single-phase, 250 VRMS, 15/16A (for surge operation up to 10 kV)(normally shipped with 125V NEMA 5-15 EUT connector, unless otherwise specified) |
| E4552kV |
Single-phase, 277 VRMS, 32A (for surge operation up to 10kV) |
| E4553kV |
Three-phase, 480 VRMS, 16A (for surge operation up to 10kV) |
| E4554 kV |
Three-phase, 480 VRMS, 32A (for surge operation up to 10 kV) |
| INCREASED AC LINE VOLTAGE OPTIONS FOR SURGE COUPLER/DECOUPLERS |
| E521-HV |
Upgrades the E521 to 600 VRMS |
| E522-HV |
Upgrades the E522 to 600 VRMS |
| E4552-HV |
Upgrades the E4552A or the E4552 kV to 480 VRMS |
| E4553-HV |
Upgrades the E4553A or the E4553 kV to 600 VRMS |
| E4554-HV |
Upgrades the E4554A or the E4554 kV to 600 VRMS |
| VOLTAGE AND CURRENT MONITORING FOR COMBINED SURGE/EFT COUPLER/DECOUPLERS |
| E4551-VI |
Enhanced V & I monitoring: Adds 3 wire automatic mode selection for surge V and I monitoring to E4551A or kV |
| E4552-VI |
Enhanced V & I monitoring: Adds 3 wire automatic mode selection for surge V and I monitoring to E4552A or kV |
| E4553-VI |
Enhanced V & I monitoring: Adds 5 wire automatic mode selection for surge V and I monitoring to E4553A or kV |
| E4554-VI |
Enhanced V & I monitoring: Adds 5 wire automatic mode selection for surge V and I monitoring to E4554A or kV |
| DC OPTION FOR COMBINED SURGE/EFT COUPLER/DECOUPLERS |
| E45XX-DC |
Allows the use of combined Surge/EFT Coupler/Decouplers on DC powered main |
| PQF MODULES |
| IEC 61000-4-11 |
EP61 |
Swell/Dip/Interrupt Simulator for single-phase AC lines to 240V RMS, 16A |
| IEC 61000-4-11 |
EP62 |
Swell/Dip/Interrupt Simulator for single-phase AC lines to 240V RMS, 32A |
| ECAT ACCESSORIES |
| B-ECAT |
Docking bay for additional ECAT Modules (one included with each Control Center, maximum configuration is six |
| HB-ECAT |
High docking bay required for E4553A, 44554A, E4553kV and E4554kV Coupler/Decouplers only |
| S-ECAT |
ECAT Floor Stand with casters (required for ECAT Systems with three or more docking bays, HB-ECAT is |
| Note: S-ECAT not required with E515, E521, E522 or E4556. Blank Plug-in Module. Required when only a single 1/2 width module is installed in a docking bay |