Portable Recorder / Reproducer
The Model RSR 512 Portable Recorder/Reproducer is a versatile multi-channel instrumentation recorder that combines the capabilities of FM recording with the accuracy of digital recording. It converts analog data to digital form for recording onto ST-120 cassettes and provides both analog and digital outputs. The Model RSR 512 is a precision voltage recorder, with accuracies 10 to 30 times that of analog recorders.
Applications
- PCM telemetry recording
- Synthetic Aperture Radar (SAR) image recording
- Compressed digital video images
- Satellite ground station recording
- Ordinance and weapon system testing
- Preflight system testing
- Flight test data collection and reproduce
- Rocket and jet engine test data acquisition
- Launch vehicle assembly monitoring
- Guidance system testing
- Multi-variable system failure analysis
Specifications
| GENERAL |
| Size: |
10-1/2 H x 17-3/4 W x 22-1/2 D inches (267 H x 434 W x 572 D mm) |
| Weight: |
Average 16 x 16 channel record/reproduce channels approximately 70 lb (32 kg) |
| Power: |
AC/DC 90 to 254 V, 47 to 440 Hz,11 to 32 Vdc |
| Power Consumption: |
250 W typical |
| TAPE TRANSPORT |
| Record/Reproduce Method: |
PCM recording |
| Inputs: |
Analog and digital |
| Outputs: |
Analog and digital |
| Tape: |
EIAJ standard magnetic ST-120, 1/2-inch tape cassette |
| Record Format: |
Helical scan |
| Record/Reproduce Head: |
Quad-head, azimuth system |
| Erase Head: |
Full width |
| Tape Speed: |
512:1 (80.8 mmps to .16 mmps) Tape speed automatically selected for optimum recording time, or manually set by user, to extend time compression and expansion in the reproduce mode |
| Record Time: |
50 minutes to over 426 hours(Record time based upon number of data channels, data bandwidth and sample density) |
| Start/Stop Time: |
Approximately 5 seconds from launch point |
| Fast Forward/Rewind Time: |
Approximately 170 seconds Controls F. FWD, REW, PLAY, STOP, REC, EJECT |
| Shuttle and Search: |
Shuttle and search from: Test name, Record number, Date, Time, Stopwatch time, Event number, or Block number |
|