Rentals - Sales - Service
Advanced Test Equipment Corporation
1-888-404-ATEC (2832)

 


spacer
Home - Analyzers
Minolta T-1
Minolta T-1 Illuminance Meter

Minolta Illuminance Meters offer excellent light-measuring capabilities with superb accuracy and simple operation. This is achieved by combining a silicon photocell with a microprocessor for compact, lightweight design. Their convenience and portability are invaluable for the control of lighting in industrial and recreational areas, as well as in laboratory and environmental control applications.

Measuring time can be adjusted for accurate readings of both continuous and flickering light sources. Illuminance deviation between sources can also be determined, or integrated illuminance over a period of time can be calculated. Three models are available, offering different features to meet any user requirement. Minolta Illuminance Meters are ideal for measuring illumination and exposure levels in a wide variety of industrial, recreational, and scientific applications. The Minolta Model T-1, with a metering range of 0 .01 to 99,900 lux (0 .001 to 9,990 ft-C), is ideal for measurements in most situations.

Technical Details:

  • Type: Multi-function illuminance meter with microprocessor and liquid-crystal display for continuous and flickering light sources

  • Receptor: Silicon photocell; receptor head detachable

  • Spectral response: 400 to 760 nm within ± 2% (integrated) of CIE photopic luminosity curve

  • Response time: "FAST" setting: lmsec. (0.001 sec) "SLOW" setting: 1 sec.

  • Measuring functions : Illuminance in lux (x) or footcandles (ft-c); integrated illuminance in lux-hours (lx .h) or footcandle-hours (ftc .h); integration time in hours (h)

  • Measuring ranges:
    Illuminance:
         0.01 to 99,900 Ix (0.01 to 300,000 lx*)
         0.001 to 9,990 ft-c (0.001 to 30,000 ft-c*)
              *analog output ranges
              5 ranges in Manual mode

  • Integrated illuminance:
         0.01 to 999,000 lx .h
        0 .001 to 99,900 ft-c.h

  • Integration period: 0.01 to 999 hours

  • Accuracy: ± 2% of recording, ± 1 digit in last changing display position

  • Analog output : 1 my per digit; 3v at maximum reading; 10 kilo ohms impedance

Please contact us for more information on the Minolta T-1 Illuminance Meter


Featured Products:

Rent an Haefely ECompact 4 Transient Immunity Test Set

Haefely ECOMPACT4
Transient Immunity Test

Voltech PM6000
Voltech PM6000
Power Analyzer



IFI T4026-40
TWT Amplifier

Varian 956 Porta Test
Teseq NSG 438
ESD Gun

Solar 2654-1
Solar 2654
Transient Generator

Terms & Conditions Privacy Notice Site Map Terms of Use
Copyright © 1996-2009  |  Advanced Test Equipment Rentals  |  All Rights Reserved